When it occurs
Air contains water vapor, and the temperature at which that vapor begins to condense is called the dew point. If a surface is colder than the dew point of the air in contact with it, liquid water forms on it. The air does not have to be very humid: it is enough for the surface to be cold enough.
Typical situations
- Cold equipment moved into a warm, humid environment.
- An outdoor panel whose temperature drops overnight and which warms up at dawn with humid air inside it.
- An environmental chamber going from low temperature to mild conditions with the sample still cold.
- Cold pipes or walls in contact with humid indoor air.
Why it causes damage
Condensed water is mostly pure water, but it dissolves dust, salts and residues on the surface and becomes conductive. It then creates leakage paths between conductors, short circuits, corrosion of contacts and terminals, and tracking on insulation. In mechanical parts, it promotes oxidation and degrades lubricants.
What the engineer sees
Droplets inside an enclosure, insulation with tracking marks, intermittent failures in the morning or after sudden temperature changes, and localized rust at cold points. Often the failure appears after the condensation, when the moisture has already evaporated, so only the trace of corrosion remains.
How it is prevented
- Keep equipment slightly above the dew point with low-power heaters.
- Let the equipment acclimate before opening its packaging or energizing it.
- Ventilate or dehumidify the air.
- Thermally insulate cold surfaces.
- Seal enclosures and use desiccants or membrane vents.
On energized or high-voltage equipment, inspection and any action must be handled by qualified personnel in accordance with the applicable regulations.