What it actually does
An electronic load replaces the real load of a power supply, battery or converter. Instead of fixed resistors, it uses power transistors in their linear region; a control loop compares the desired quantity with the measured one and adjusts the transistor’s conduction. The absorbed energy is converted into heat, so the instrument depends on heat sinks and ventilation.
Operating modes
- Constant current: maintains the set current regardless of the source voltage. This is the basic mode for discharging batteries and testing regulation.
- Constant voltage: draws the current needed to hold a voltage at its terminals; useful for emulating a battery or testing current sources.
- Constant resistance: behaves like a programmable resistor, so the current follows the voltage.
- Constant power: adjusts the current to absorb a fixed power, as a converter fed from the source would do.
Dynamic response
In addition to steady-state operation, many loads generate current steps between two levels with a programmable slope. This makes it possible to observe how a source responds to a sudden change: the overshoot, the transient voltage dip and the recovery time. The speed at which the load changes level and the inductance of the cables limit what actually reaches the source.
What the engineer sees in practice
The load’s own voltage and current readings serve as an approximate reference, but for rigorous measurement an independent instrument is advisable. With long cables, the voltage drop in them means the load sees less than the source output; this is why measurement with separate sense terminals exists. Another frequent observation is that, at very low currents, regulation loses accuracy because the instrument’s noise and offsets weigh more.
When it does not apply or care is needed
- An electronic load does not replace a reactive load or a motor: it does not reproduce inertia or stored energy.
- Sources with very fast feedback can interact with the load’s loop and oscillate; if instability appears, try another mode or a speed adjustment.
- Power limits depend on temperature; with blocked ventilation the instrument reduces capacity or protects itself.
- Reverse polarity and overvoltages can damage the input stages.
When the source under test works with hazardous voltages, connections must be made by qualified persons in accordance with the applicable safety regulations.