Meaning
Co-channel (cocanal, or co-canal, in Spanish) means that two signals occupy the same frequency channel. It applies to transmitters, to networks and to the interference they produce. Saying that two access points are co-channel is the same as saying they use the same channel, so they hear each other and share the medium.
Difference from adjacent channel
An adjacent channel is the immediate neighbor in frequency. Adjacent-channel interference comes from energy spilling outside the transmitter’s channel or from a receiver that does not filter well. In the co-channel case, the interfering source occupies exactly the band of interest and no filter can separate it, because it is already inside. The solutions are different: for co-channel interference you work on planning, distance and power; for adjacent-channel interference, on filters and frequency separation.
Where the term is used
- Cellular and radio networks: frequency reuse places distant cells on the same channel; the reuse distance must be sufficient for co-channel interference to stay below the tolerable level.
- Wi-Fi: nearby access points on the same channel share airtime, even if they do not interfere with each other destructively.
- Radio links: two links with the same frequency and polarization can disturb each other if their antennas are not sufficiently isolated.
How it is measured
The usual indicator is the ratio between the desired signal and the co-channel signal, expressed in decibels. A receiver tolerates a certain amount of interference depending on its modulation; high-order modulations need a higher ratio. On a spectrum analyzer it can be recognized because the interfering signal appears within the bandwidth of the channel itself, with a spectral shape similar to that of the desired signal.
Usage note
In Spanish the word is written cocanal, without a hyphen. It is a different term from intersymbol interference or thermal noise: the former arises within the signal itself and the latter is inherent to the receiver.