What is meant by EUT
The EUT is what gets tested: a device or system with its cables, accessories and operating modes. In an electromagnetic compatibility test, the result belongs not to the design in the abstract but to a specific sample and configuration. That is why the term appears in every test plan and report.
Why the configuration rules
Emission and immunity change with the cabling, the connected accessories, the load, the operating mode and even the position of the cables. A device that passes with short cables can fail with long ones because they act as antennas. For that reason, the following are defined in advance:
- Which modules and accessories are part of the EUT and which are auxiliary equipment that merely keeps it running.
- Which cables are connected, of what type, at what length and how they are laid out.
- Which mode it operates in during the test, normally the one that produces the highest emission or is the most susceptible.
- Which function is monitored and how a failure is recognized.
EUT and auxiliary equipment
Auxiliary equipment serves to exercise the EUT or to observe its response, for example a load, a signal simulator or a computer reading data. If the auxiliary equipment contributes its own emission or is susceptible, it can distort the result. It is isolated with filters, shielding or suitable cabling so that what is measured corresponds to the EUT.
How it is documented
A good record includes the equipment identification and hardware and software versions, photographs of the configuration, a description of the operating modes and the modifications made during the test. If a component is changed after a failure, the new state is a different EUT and may require tests to be repeated.
How to interpret the result
A pass applies to the sample and configuration tested. Extending it to product variants requires a technical analysis showing that the changes do not affect electromagnetic behavior.