What it quantifies
When a noise current flows on the outside of a shield, a small part of the voltage appears on the inside and adds to the signal. Transfer impedance (Zt) expresses that relationship: voltage induced on the inside per unit length divided by the current on the shield, in units of ohms per meter. It is a property of the cable shield, independent of the signal it carries.
How it is measured
The classic method is the triaxial method. The cable under test is placed inside a concentric metal tube that forms a coaxial circuit between the cable shield and the tube. A generator injects current into this outer circuit, so that the current flows on the cable shield. At the end, a receiver measures the voltage induced between the inner conductor and the shield. The ratio between the two, corrected for length, gives the transfer impedance.
- The system is calibrated with the connecting cables and the signal level.
- A known current is applied to the outer circuit.
- The inner voltage is measured at the end of the cable, which is terminated in a defined load.
- The ratio is calculated at each frequency and normalized by length.
How it changes with frequency
- At very low frequency it coincides with the DC resistance of the shield; the more conductor, the lower it is.
- As frequency rises, currents concentrate on the outer surface (skin effect) and transfer through a solid shield decreases.
- In a woven braid there are gaps between strands, and coupling through them (coupling inductance) causes the transfer impedance to increase with frequency.
- Combining braid with foil usually improves behavior at high frequencies.
An example of how to read it
If two cables have similar shield resistance, but one shows a Zt that rises at high frequency, that second cable has poorer braid coverage. For fast signals or radio interference, the upper part of the curve is decisive; for low-frequency noise, the initial part matters.
Zt describes only the cable. In a real system, the quality of the shield termination at the connectors can ruin that advantage.