Objective and scope
A pre-assessment makes it possible to discover problems during development, when correcting them is cheap. It does not seek to produce a certifiable value but to answer an engineering question: did this change improve or worsen the behavior?
Useful instruments
- Spectrum analyzer with preamplifier and peak detector, for quick exploration.
- Near-field probes, for locating sources.
- Current clamp, for estimating common-mode current on cables.
- Line impedance stabilization network, for emissions conducted through the power supply.
- Antenna and metal plane if a radiated estimate is wanted, accepting that the environment will not be controlled.
Ambient environment: the main obstacle
Outside a chamber, the spectrum contains radio stations, cellular telephony and wireless networks. To distinguish them from the emission of the equipment, measure with the equipment off and on, and compare. A signal that appears and disappears with the equipment belongs to the equipment. Changing the position or switching off the auxiliary equipment also helps.
Recommended practice
- Fix a test configuration and document it.
- Take a baseline measurement of the initial state.
- Change only one thing at a time and repeat the measurement with the same configuration.
- Save the spectra for comparison.
- Also run basic immunity tests, such as electrostatic discharges with a gun, if you have one and trained personnel.
How to interpret the result
Results obtained outside a validated facility carry greater uncertainty than those from a test laboratory. If a level falls just below the limit, that is not evidence of compliance: a wide margin is sought. If it is clearly above the limit, that is a reliable sign that a problem exists.
It is advisable to repeat the pre-assessment after each relevant design change: a change of reference plane, cable or power supply can alter emissions more than expected.