What the filter is for
An input filter performs two functions: it stops noise generated by the equipment from leaving through the mains cable, and it prevents mains noise from entering and affecting the equipment. To do so, it presents a high series impedance to the noise and a low-impedance shunt path.
Basic elements
- X capacitors between line and neutral: attenuate differential noise.
- Y capacitors from each line to ground: shunt common-mode noise. Their value is limited by the leakage current permitted for safety.
- Common-mode choke: high impedance to common noise without saturating with the load current.
- Differential inductors: the leakage inductance of the choke is often sufficient.
How the circuit conditions it
The actual attenuation of a filter depends on the source and load impedances between which it is connected, which are unknown and vary with frequency. A filter that shows good attenuation on a datasheet may perform less well in the equipment. In addition, inductors and capacitors form resonances that amplify noise at certain frequencies if there is no damping.
Mounting: what most affects performance
- Install it where the cable enters the enclosure, so that there is no noisy wiring ahead of the filter.
- Keep the input and output conductors separate; if they run together, noise couples across the filter.
- Fasten the filter case to a metal surface with good contact, so that the shunt path to ground is short.
- Avoid long ground wires: their inductance reduces the action of the Y capacitors at high frequencies.
What to check if it does not work
Check whether the choke saturates with the load current or with the DC component; verify whether the noise is arriving by another path (radiated coupling onto the mains cable inside the enclosure); and confirm that the filter ground actually connects to the intended reference.
The mains supply presents an electrical hazard. The mounting and testing of input filters must be carried out by qualified personnel, in accordance with the applicable regulations.