What is shielding effectiveness?

Shielding effectiveness measures how much a metal barrier attenuates an electromagnetic field: it is the ratio, in decibels, between the field without the shield and the field with the shield at the same point.

Definition

Shielding effectiveness (SE) compares the field measured at a point without the shield with the field measured at the same point with the shield installed. It is expressed in decibels: twenty times the logarithm of the ratio of field strengths. A higher value means greater attenuation. It can be defined for the electric field, the magnetic field or a plane wave.

How a shield attenuates

  • Reflection: the wave strikes an impedance discontinuity between the air and the metal, and part of it is reflected. This dominates for electric fields and at high frequencies with good conductors.
  • Absorption: the energy that enters is dissipated inside the material as induced-current losses. It increases with thickness, conductivity and permeability, and depends on the skin depth, which decreases as frequency rises.
  • Multiple reflections: relevant only in very thin shields, where they somewhat reduce the total effectiveness.

Why it depends on the field and the frequency

A low-frequency magnetic field is the hardest to shield with thin copper or aluminum sheets, because it is barely reflected and absorption is small. For this case, high-permeability materials are used, which divert the magnetic flux. For electric fields and plane waves, on the other hand, a continuous conductive metal provides very high attenuation with minimal thickness.

Ideal material versus real shield

A continuous metal sheet has a high theoretical effectiveness, but a real enclosure is not a continuous sheet. It has seams, covers, ventilation, connectors and cable holes. Each aperture lets energy through, and the overall value is set by the worst aperture, not by the material. That is why the difference is usually large when comparing figures from a material catalog with the behavior of a piece of equipment.

How to interpret an SE value

  • Verify which frequency and which type of field the figure refers to.
  • Ask whether it is a flat sample or a complete enclosure.
  • Laboratory data on a sample does not carry over directly to the final product.

Shielding effectiveness is a design and verification quantity: it indicates how much margin exists between the external field and the field that reaches the circuits or, conversely, between the internal source and what escapes from the enclosure.