What being immune means
Immunity is the complementary side of emission in electromagnetic compatibility. It measures how well the equipment tolerates external disturbances. It does not mean being unaffected in any way, but rather maintaining acceptable performance, defined in advance for that equipment, while the disturbance is applied to it.
Disturbances considered
- Electrostatic discharges: charge transfer from a person or object to the equipment, with very fast pulses.
- Radiated radio-frequency fields: from nearby transmitters, which induce currents in cables and traces.
- Conducted radio-frequency disturbances: injected through cables.
- Electrical fast transients: bursts caused by the switching of inductive loads.
- Surges: from switching operations on the network or distant lightning discharges.
- Voltage variations: dips, interruptions and fluctuations of the power supply.
- Low-frequency magnetic fields: near transformers or high-current conductors.
How it is evaluated
Each disturbance is applied with a generator of defined characteristics, at severity levels established by the product standard. During application, the equipment is observed and its behavior is classified using acceptance criteria. In general, a distinction is made between normal operation during the test, temporary loss of function that recovers on its own, loss that requires operator intervention and permanent failure.
What the engineer sees
What is observed are resets, lockups, erroneous readings, noise on an analog signal or interrupted communications. Tracing the cause means following the path the disturbance takes to reach the sensitive circuit, which may be an input line, a ground reference or a clock.
How to design to tolerate it
- Protect the ports with suppression and filtering elements.
- Keep loops small and ground references solid.
- Use robust software, with watchdog supervision and fault recovery.
Tests involving high voltages or electrical hazards must be carried out by qualified personnel, in accordance with the applicable regulations.