Two ways to control the environment
Every antenna and radiated emissions measurement needs an environment whose effect is known. An anechoic chamber achieves this by eliminating reflections with absorber and shielding the enclosure. An open-area site achieves it with clear terrain and a metal ground plane, so that the only significant reflection is from the ground, and its contribution can be predicted.
Comparison
| Aspect | Anechoic chamber | Open-area site |
|---|---|---|
| External noise | Isolated by the shielding | Present: radio, television and other sources |
| Weather | Independent | Can interrupt the measurement |
| Object size | Limited by the enclosure | Large objects can be measured |
| Reflections | Reduced by absorber | Ground reflection, known and intended |
| Repeatability | High | More dependent on conditions |
When each one is preferred
- Anechoic chamber: radiation patterns, gain and sensitive measurements that external signals would affect, or when repeatability and continuous work are required.
- Open-area site: very large or heavy equipment, and emissions measurements that were historically defined for that environment.
What the engineer sees in the data
On an open-area site, the received level varies with antenna height, because the direct signal and the signal reflected from the ground add or subtract. That is why a height scan is performed to find the maximum. In an anechoic chamber that variation does not exist, but ripple can appear from residual reflections off the absorber.
When neither is enough
Some emissions chambers are not fully anechoic but have a reflective floor to emulate an open-area site, and they are called semi-anechoic. For low frequencies, where absorber is not very effective, an open-area site or an equivalent site may remain the reference.