What is thermal runaway in lithium batteries and what causes it?

Thermal runaway is a chain reaction in which the heat generated inside a cell accelerates reactions that generate more heat; it is caused by internal short circuits, overcharging, mechanical damage, overheating and manufacturing defects.

The central idea

In a lithium cell, a rise in temperature accelerates the internal chemical reactions, many of which are exothermic. If the heat generated exceeds what the cell can dissipate, the temperature rises further and the reactions speed up in a positive feedback spiral. That self-sustaining process is thermal runaway.

Typical sequence

  1. An initiating event raises the local temperature.
  2. The protective layer on the anode decomposes and releases heat.
  3. The separator melts or shrinks and an internal short circuit can occur, generating more heat.
  4. The electrolyte decomposes and releases flammable gases; the internal pressure opens the vent.
  5. In some cathodes, decomposition releases oxygen, which feeds combustion.
  6. Heat is transferred to neighboring cells and can propagate through the pack.

What causes it

  • Internal short circuit: from manufacturing defects, particles, separator damage or lithium plating.
  • Electrical abuse: overcharging, overdischarging or an external short circuit.
  • Thermal abuse: exposure to external heat or cooling failure.
  • Mechanical abuse: crushing, penetration or impact.

What is seen before and during

Before the event there may be an abnormal temperature rise in a cell, an unexpected voltage drop or an increase in self-discharge. During the event there is a very rapid temperature increase, gas emission and, on occasion, flames.

How the risk is limited

The management system monitors voltage, current and temperature and disconnects under hazardous conditions. The pack design includes separation between cells, thermal barriers, vent paths and cooling. Abuse tests in containment chambers evaluate whether a failure propagates. Chemistry plays a role: some are more stable than others, but none is exempt.

Any work with damaged or suspect batteries must be done by qualified personnel, with emergency procedures and suitable equipment.