How is signal integrity evaluated on a digital line?

Signal integrity on a digital line is evaluated by observing, at the receiver, the edge shape, overshoot, ringing from reflections, noise and jitter, with a bandwidth and probe connection that do not distort what is being measured.

Why a digital signal is analog

The data are ones and zeros, but the signal that carries them is a voltage that is continuous in time, with finite edges. When the line is long enough or the edges fast enough, it behaves like a transmission line: if its impedance does not match that of the source or load, part of the energy is reflected and superimposed on the signal. What matters is what the signal looks like at the receiver at the decision instant.

What to look for in the waveform

  • Rise and fall time: too slow reduces the timing margin; too fast increases reflections and interference.
  • Overshoot and undershoot: they exceed the logic level and can cause damage or trip protections.
  • Ringing and steps: signs of reflections from impedance mismatch. A step on an edge that stalls halfway can cross the threshold later than it should.
  • Crosstalk: activity induced on a quiet line by its neighbors.
  • Power supply noise and ground bounce: reference variations when many outputs switch at once.

Eye diagram and jitter

Overlaying many bits in a single time window produces the eye diagram. Its vertical opening indicates the noise margin and its horizontal opening, the timing margin. Jitter is the variation in the timing of the edges relative to their ideal position, and it closes the eye horizontally.

Measurement conditions

  1. Measure at the receiver or as close to it as possible, because that is where the decision is made.
  2. Use enough bandwidth to include the harmonics that define the edge; as a rule, the bandwidth needed grows as the rise time shrinks.
  3. Use a low-capacitance probe and a minimal ground connection, so that you are not the one causing reflections and oscillations.
  4. Trigger stably, with a clock reference if there is one.

How to interpret the result

If the problems disappear when you add a termination or shorten a trace, the source was reflection. If they change with activity on other lines, suspect crosstalk or power supply noise.