Why does a wireless link drop at specific times?

A link that always drops at the same time usually has a cause that is also periodic: interference on a schedule, propagation changes during the day, or machine activity that alters the environment.

The clue is the schedule

When a failure repeats at similar times, the problem is almost never random. Something changes with the clock: who is transmitting nearby, how the signal propagates or which machines are running. Finding that change is more useful than checking the link equipment, which is usually fine.

Most frequent causes

  • Scheduled interference: other networks or radios that turn on at shift change, at mealtimes or while a process is running; microwave ovens and welding equipment generate noise in the 2.4 GHz band while they operate.
  • Traffic saturation: if many users or devices use the same access point at certain times, the link does not break over the air but becomes congested and looks like an outage.
  • Propagation: on long links, temperature and humidity change the refractive index of the atmosphere. Before dawn or at sunset, fading and reflections can appear and reduce the margin.
  • Moving obstacles: cranes, vehicles or containers that occupy the path only during certain periods.
  • Electrical noise from the plant: drives and motors that start on a fixed schedule.

How to diagnose it

First, record time-stamped values of the received signal level, the signal-to-noise ratio and the link’s error or retry rate. Then compare them with the operating schedule. Next, observe the spectrum on site during the problem period, ideally with a waterfall or persistence view, which shows intermittent emissions that a normal sweep misses.

How to interpret the result

  • If the received level drops without the noise rising, the problem lies in the path or in propagation.
  • If the level holds but the noise or the level of other emissions rises, it is interference.
  • If both are normal but there is packet loss, check for saturation and review the network configuration.

The solution follows the cause: change the channel or band, use directional antennas or filters, adjust the power or move the route. Replacing equipment without identifying the cause usually means the problem comes back.