Temperature calibration with a dry well
Calibration in Monterrey with a temperature dry well.
We calibrate temperature instruments with a dry well, a stable, high-precision thermal source. We verify thermometers, RTD probes, thermocouples, temperature sensors, and industrial transmitters and indicators. We compare the instrument under test against traceable reference standards over a wide temperature range. The service is performed at our laboratory or at the client’s facilities.
Calibration and adjustment of industrial signals
Professional calibration and adjustment of industrial signals with a photographic record.
We calibrate and adjust the signals of measurement, control and automation systems. We verify and adjust analog and digital signals: 4–20 mA, 0–10 V, RTD, thermocouples, frequency, pulses, pressure, temperature, level, flow and other process variables. We use calibrated instrumentation with metrological traceability.
HART temperature and pressure sensors
Calibration and adjustment of HART temperature and pressure sensors.
We calibrate and adjust HART temperature and pressure sensors to verify and correct their measurement performance, with reliable, traceable readings. The service includes signal evaluation, HART parameter configuration, zero and span adjustment where applicable, verification of measurement points and documentation of results.
Keysight 3458A 8.5-digit digital multimeter
Rental of, or calibration with, the Keysight 3458A 8.5-digit digital multimeter
The 8½-digit digital multimeter is a high-precision instrument for calibration, metrology and engineering laboratories. It measures DC and AC voltage, current, resistance and other electrical quantities. Its resolution and stability allow it to be used as a reference standard to calibrate and verify multimeters and lower-resolution equipment, always taking into account the accuracy, uncertainty and traceability each calibration requires.
Pneumatic and hydraulic pressure calibration
Calibration of pneumatic and hydraulic pressure systems.
We perform industrial pressure and process calibration in Monterrey with pneumatic and hydraulic systems. We verify pressure gauges, transmitters, indicators, pressure switches, sensors and other pressure instruments. We compare their readings against measurement references to determine their accuracy and their behavior at different points in the range. The service supports maintenance, process control and quality assurance.
Dielectric hot sticks
Calibration and certification of dielectric hot sticks in Monterrey
Certification service for dielectric hot sticks, to verify that they retain their insulation and can be used safely in work on energized electrical installations. The tests include visual inspection, assessment of mechanical integrity and a high-voltage dielectric test. They make it possible to detect contamination, moisture, cracks, material deterioration or any condition that compromises operator safety. The service is intended for companies in the electrical, industrial, energy and maintenance sectors.
On-site calibration with photographic evidence
On-site calibration with reports that include photographic evidence.
A calibration should offer more than a certificate. Many services can be performed at the client’s facilities. Laboratory services include photographic evidence of the condition of the instrument, its identification, the connections made, the standards used and the calibration conditions. This documentation strengthens traceability, provides transparency and makes quality audits easier.
Pneumatic pressure up to 3000 PSI with Fluke
Calibration of pneumatic pressure sensors up to 3000PSI in Monterrey.
We calibrate pneumatic pressure sensors, transmitters, switches and gauges with ranges up to 3000 PSI. We use Fluke 754 process calibrators, high-accuracy pressure modules and precision pneumatic pumps. We verify the instrument at multiple calibration points against traceable reference standards to determine errors, deviations and repeatability. The service is performed at our laboratory or at the client’s facilities, and includes a technical report.
Fluke 754 and 750P Series pressure modules

Calibration of pressure sensors with Fluke calibrators and modules.
We calibrate pressure sensors, transmitters and gauges in Monterrey with Fluke 754 process calibrators and Fluke 750P Series pressure modules. We apply known pressures using reference standards, compare the response of the instrument under test and verify its performance at different operating points. This lets us detect deviations and confirm that it operates within the tolerances specified by the manufacturer.
Calibration of our equipment
All our test and measurement equipment is maintained under a controlled calibration program, with certificates traceable to NIST (National Institute of Standards and Technology) standards. Calibration services are performed by providers accredited by PJLA (Perry Johnson Laboratory Accreditation), as applicable.







