WiMAX (IEEE 802.16): features and differences from Wi-Fi (IEEE 802.11)

A technical explanation of WiMAX, the wireless broadband technology based on the IEEE 802.16 standard, and how it compares with Wi-Fi. For technical managers evaluating last-mile links and metropolitan networks.

What WiMAX is

WiMAX stands for “Worldwide Interoperability for Microwave Access”. It is the brand that certifies that a product complies with the “IEEE 802.16” wireless access standards. These standards will allow connections at speeds similar to ADSL or cable modem, without cables, up to a distance of 50-60 km. The standard will be compatible with earlier ones, such as that of Wi-Fi (IEEE 802.11).

The impact of this wireless technology could be extraordinary, because it brings together elements that favor its expansion:

  • relatively low deployment cost;
  • long range, up to 50 km;
  • transmission speeds that can reach 75 Mbps;
  • no line of sight needed;
  • available with criteria for both voice and video;
  • end-to-end IP technology.

In addition, depending on the bandwidth of the channel used, a base station can support thousands of users, clearly more than a WLAN.

WiMAX will be the basis of metropolitan Internet access networks. It will serve to facilitate connections in rural areas and will be used in the business world to implement internal communications. Its popularization will also mean the definitive takeoff of other technologies, such as VoIP (voice calls over the IP protocol).

WiMAX is intended mainly as a last-mile technology and can be used for access links, MANs or even WANs. It stands out for its capacity as a carrier technology, over which IP, TDM, T1/E1, ATM, Frame Relay and voice can be transported. That makes it suitable for large corporate voice and data networks and for telecommunications operators.

Several European and American operators were testing this technology with fixed receivers. A product catalog similar to the one the industry offered for Wi-Fi and 3G was expected, with access from mobile devices, laptops, phones, PDAs, etc.

WiMAX features

  • Distances of up to 80 kilometers, with highly directional, high-gain antennas.
  • Speeds of up to 75 Mbps, 35+35 Mbps, provided the spectrum is completely clean.
  • Easy to add more channels, depending on each country’s regulations.
  • Configurable, non-fixed bandwidths, subject to the spectrum ratio.
  • Allows the communication channel to be divided into small subcarriers (two types: guard and data).

WiMax would work in a similar way to WiFi, but at higher speeds, over greater distances and for a larger number of users. It could solve the lack of broadband access in suburban and rural areas, which telephone and cable companies do not yet offer.

Parts of a WiMAX system

  • WiMAX towers, which provide coverage of up to 8,000 square kilometers depending on the type of signal transmitted.
  • Receivers: the cards that connect to the PC, laptop, PDA and other equipment to get access.

Two ways of delivering the signal

  • With objects between the antenna and the receiver. It operates at low frequencies (between 2 and 11 GHz) to avoid interference from those objects. This reduces the available bandwidth. The antennas for this service have a coverage of 65 square km, more or less like those of mobile phones.
  • With nothing in the way and direct line of sight. It operates at very high frequencies, on the order of 66 GHz, with a large bandwidth. The antennas for this service have a coverage of up to 9,300 square km.

Ordinary users will use the first type of service, the low-frequency one. Although it is the less favorable service, a big difference from current WiFi will be noticeable in two respects: speed rises to as much as 70 Mbps and the signal is valid up to 50 km in favorable atmospheric conditions.

Trials have been seen such as the one at the Universidad Politécnica de Valencia, the one by the Mijas town council and one developed by Alcatel at the Paris airport.

Main features of the standard

  • Channel widths between 1.5 and 20 MHz.
  • Uses OFDM (Orthogonal Frequency Division Multiplexing) and OFDMA (Orthogonal Frequency Division Multiple Access) modulation with 256 and 2048 carriers respectively, which allow high transfer speeds even in unfavorable conditions. This modulation is also used in digital TV, by cable or satellite, and in Wi-Fi (802.11a), so it is sufficiently proven.
  • Incorporates support for smart antenna technologies, which improve efficiency and coverage. These antennas are typical of 3G cellular networks. They improve spectral efficiency, reaching twice that of 802.11.
  • Includes adaptive modulation mechanisms: the base station and the user equipment connect with the best possible modulation according to the characteristics of the radio link.
  • Supports several hundred users per channel, with high bandwidth, and is suitable for both continuous and bursty traffic. It is protocol-independent: it carries IP, Ethernet, ATM, etc., and supports multiple services simultaneously with Quality of Service (QoS) in 802.16e. That makes it suitable for voice over IP (VoIP), data and video.
  • Provides for mesh networks, so that users can communicate with each other without needing a direct line of sight between them.
  • For security, it includes user authentication and data encryption with the triple DES and RSA algorithms.

Wi-Fi versus WiMAX

WiMAX is to the 802.16 standard what Wi-Fi is to 802.11. WiMAX was not designed to compete with Wi-Fi, but to complement it where it falls short.

Wi-Fi (802.11)

The first wireless standard (802.11) was developed as an alternative to structured LAN cabling and to offer wireless Ethernet connectivity. Wi-Fi certification was created to guarantee interoperability between 802.11 products from different manufacturers. To understand its applications, imagine an Ethernet network inside an office in the nineties.

Wi-Fi was designed for indoor wireless environments, and non-line-of-sight (NLOS) capabilities are possible only over a few meters. Even so, many Internet service providers (ISPs) deployed Wi-Fi radios for last-mile service, and the services on those networks were quite limited.

In recent years Wi-Fi and Ethernet have been developed to adapt to changes in data networks. This includes better security (encryption), virtual networks (VLANs) and basic voice support (QoS). In conclusion, Wi-Fi was designed for local area networks (LANs), over short distances within an office.

WiMAX (802.16)

WiMAX is based on the 802.16 standard, designed specifically as a last-mile solution and focused on the requirements for providing commercial-grade service. Its design takes into account the need for several service protocols.

A WiMAX connection supports packetized services such as IP and voice over IP (VoIP), as well as switched services (TDM), E1/T1 and traditional voice (class-5). It also supports ATM and Frame Relay interconnections. It offers several service levels (MIR/CIR) to provide different data rates according to the subscriber’s contract.

A WiMAX radio can deliver several service channels from the same physical connection. In this way, several subscribers connect to the same radio (CPE), each with a private connection, with the protocol and service level they require. This makes it possible to serve multiple subscribers in the same building (MDU).

In addition, OFDM transmission is a robust solution for operating without line of sight (N-LOS) at distances of several kilometers. This is a mandatory requirement for a last-mile wireless service business case.

WiMAX and Wi-Fi are complementary solutions for two quite different applications. WiMAX was designed for metropolitan area networks (MANs), also known as the last mile. Wi-Fi was designed for local area networks (LANs), also known as on-site distribution.

Applications

The first products will be outdoor units that work with or without line of sight between devices, with limited bandwidth and no mobility. The equipment will have to be installed in each home. At this stage, performance will be the same as basic Internet access.

The second generation will be for indoor use, with self-installable modems similar to cable or DSL modems. WiMAX networks will then offer mobility, so that customers can take their laptop or WiMAX modem anywhere with coverage.

Secure networks

The security and integrity of information transmitted over wireless networks has been criticized because, according to some experts, it could interfere with other communication networks or be exposed to data theft. This field advanced very quickly, and wireless networks reach security levels very similar to those of wired networks.

For security, WiMAX incorporates 3DES (Triple Data Encryption Standard). It was expected to incorporate AES (Advanced Encryption Standard) when large-scale commercialization began.

Standardization

As happened with the Wi-Fi standard (802.11b), WiMAX promised to revolutionize the telecommunications sector. Its version of the 802.16 standard was approved during 2004 by the WiMAX Forum, an association of more than 200 computer and communications companies from around the world.

The overall WiMAX project includes 802.16-2004 and 802.16e. 802.16-2004 uses orthogonal frequency division multiplexing (OFDM) to serve multiple users by time division, in a round-robin technique executed so fast that users feel they are always transmitting or receiving.

IEEE 802.16-2004

IEEE 802.16-2004 is a recent fixed wireless access technology. It is designed as a wireless DSL replacement, to compete with cable or DSL broadband providers, or to provide basic voice and broadband access where no other access technology exists. It is also a viable wireless backhaul solution for Wi-Fi access points or, potentially, for cellular networks, particularly if licensed spectrum is used.

In general, the CPE (user equipment) consists of an outdoor unit (antenna, etc.) and an indoor modem, so a technician is required to connect a residential or commercial subscriber. In certain cases a self-installable indoor unit can be used, particularly when the subscriber is relatively close to the base station.

Self-installable CPEs would make 802.16-2004 more economically viable, because they drastically reduce a large part of the customer acquisition cost (installation and CPE). It is technically possible to design an 802.16-2004 data card, but portable devices with this solution built in did not appear to be an industry priority. The fixed version of the WiMAX standard was approved in June 2004, and interoperability testing would begin later in 2005.

IEEE 802.16e

IEEE 802.16e is designed to offer a key feature that 802.16-2004 lacks: portability and, in time, full-scale mobility. It requires a new hardware and software solution, because it is not compatible with 802.16-2004. This is not necessarily good for operators planning to deploy .16-2004 and then move to .16e.

Another important difference is that .16-2004 is based, in part, on proven, albeit proprietary, fixed wireless solutions; there is therefore a good chance that the technology will reach its performance goals. .16e, on the other hand, tries to incorporate a wide variety of proposed technologies, some more proven than others. Justification of the proposed features with performance data was modest, and the final composition of these technologies was not fully determined, so it was hard to know whether a particular feature would improve performance.

The 802.16e standard was scheduled for approval in mid-2005. That date passed and approval was expected later that year. Several vendors promised field and market trials in early 2006, and it was too early to say when the technology would be ready for commercial deployment.