Vibration: equipment rental and reports
We provide vibration predictive maintenance in Monterrey for all kinds of rotating equipment, motors, pumps, racks and piping. We carry out compressor pressure pulsation studies at natural gas stations per API STD 618. We rent analyzers of all kinds with a technical advisor to connect the equipment and operate its menus.
We are active field engineers and have worked at companies such as Panasonic, Navistar, Husmann, General Electric, Pemex, Latina, US Motors, International, Heniken and Lakeshore. We hold a seaman’s book (libreta de mar) for access to oil platforms and have experience in the mining industry and other hazardous areas. Our staff have completed courses with DC-3 (Mexican labor certificate) for access to any industry.
We are located in central Monterrey.
Predictive maintenance
Vibration analysis, lubricant analysis and power quality analysis, together with thermography, are predictive maintenance techniques. They make it possible to find the causes of potential failures before a breakdown occurs.
Implementing predictive maintenance requires a program and an organization that keep constant, rigorous track of plant components. The program follows a logical sequence: a problem is detected, studied and traced to its cause, and a decision is made on how to correct it at the right time and with maximum efficiency. It consists of three steps:
- Detection: recognizing the problem.
- Analysis: locating the cause of the problem.
- Correction: finding the time and the way to solve it.
Detection
This means finding a problem in the machinery, which is done by keeping constant, rigorous track of the vibration level. The interval between measurements depends on each piece of equipment and can range from two months to continuous measurement, according to the type of equipment and its importance in the process.
Measurement points are those where there may be a defect affecting operation: locations that house bearings, fans, gears or shaft couplings. At each point, velocity, acceleration or displacement values are taken, according to the location of the point and the characteristics of the machine. A data collector is used, with a program that stores the values from routine inspections. With the history of each point, a problem is detected when the trend of the values increases or changes noticeably.
Analysis
Once the problem has been detected, its possible causes are identified. This study is complicated and depends on the point where the defect appears and on the position and surroundings of the machine. No single feature unequivocally characterizes a cause of excessive vibration; experience, common sense and knowledge of each machine are essential.
Correction
With the problem analyzed, the actions to solve it are studied and the right time to repair it is sought, in the most efficient way and with minimum impact on production, for example during a shutdown or when the machine load is lower.
Vibration analyzers
We have the Fluke 810, whose firmware comes preset with the data needed to perform the study and deliver results automatically, as well as dynamic signal analyzers.
Vibration analyzers are used for inspection, manufacturing, production and laboratory work. They measure oscillations in machines and installations and are used to develop products, for example components or tools. They provide acceleration, velocity and vibration variation, which allows vibrations to be characterized accurately. The equipment is portable and its results can be partially stored.
We also have ultrasound technology, thermography, laser thermometers, laser alignment equipment and thickness measurement. Services: vibration analysis, shaft alignment, dynamic balancing, thermographic inspection and noise measurement.
We deliver the analysis with a professional report. The rental can include a technician experienced with the rented equipment, which saves time and cost for anyone who needs to analyze or measure quickly and safely, and eliminates the purchasing and training process.
KEYSIGHT 35660A or KEYSIGHT 35670A
The HP 35660A dynamic signal analyzer is an FFT-based instrument that performs spectrum and network measurements in electronics, mechanical testing, vibration, acoustics and other low-frequency applications. It includes test and automation functions traditionally available only with a computer: an internal programming language (HP Instrument BASIC), a built-in disk drive, limit testing and data tables. The 35670A is an FFT spectrum and network analyzer for octave, order and correlation analysis.
Our videos:
Fluke 810 available in Monterrey
The Fluke 810 is a troubleshooting tester for mechanical maintenance teams. Its diagnostic technology helps identify and prioritize mechanical problems quickly. It uses a triaxial accelerometer to make measurements faster.
Analysis of motors, fans, belts, pumps, drive chains, gearboxes, gears, couplings, compressors, spindles, shafts and more.
Our video: https://www.youtube.com/watch?v=wuYcQm9plDs