Transformer Short-Circuit Impedance Tester

Instrument for measuring transformer short-circuit impedance and judging whether the winding has deformed. For testing three-phase and single-phase transformers.

Impedance tester description

Short-circuit impedance is an important transformer parameter, and measuring it is the traditional method for judging winding deformation. According to GB1094.5-2003 and IEC60076-5:2000, the variation in short-circuit reactance is the only criterion for judging whether a transformer winding is deformed.

The low-voltage short-circuit impedance test is the most direct method for checking whether the winding has deformed after the transformer was subjected to short-circuit current in service, or to mechanical force during transport and installation. It is important for judging whether the transformer can be put into service. It is also one of the bases for deciding whether a teardown inspection is required.

Main test functions

Three-phase short-circuit impedance measurement

Displays three-phase voltage, current and power. Automatically calculates the percentage impedance voltage converted to the transformer’s rated temperature and rated current, and the percentage error relative to the nameplate impedance.

Single-phase short-circuit impedance measurement

Measures the short-circuit impedance of a single-phase transformer.

Zero-sequence impedance measurement

Zero-sequence impedance measurement is suitable for transformers with a star-connected neutral point on the high-voltage side.

Other features

  1. Measures directly within the instrument’s permitted measuring range. Beyond that range, external voltage and current transformers can be connected. The instrument allows the ratio of the external transformers to be set and directly displays the applied voltage and current values.
  2. Large, high-resolution color LCD touch screen, with Chinese-language menu and prompts and simple operation.
  3. Includes a printer for printing and displaying data.
  4. Built-in non-volatile memory that can store 200 sets of measurement data.
  5. USB flash drive interface for accessing test data.
  6. Perpetual calendar, clock function and time calibration.
  7. Wide measuring range, high accuracy and good stability. Its small size and light weight make measurement easier.

Technical parameters

Technical parameters table for the transformer short-circuit impedance tester