24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Rogowski RCP500 probe rental

Rogowski RCP500 probes for rent, available for immediate delivery, for measuring alternating current without opening the circuit.

Rogowski probe rental

We have professional Rogowski probes available for immediate delivery. A Rogowski probe measures alternating currents (AC) non-intrusively: it neither interrupts the circuit nor touches the conductor. It works by electromagnetic induction.

What is a Rogowski probe used for?

  1. Measuring high currents: it is used in industrial installations or equipment with very large currents, where other measurement methods could be dangerous or difficult to apply.
  2. Accurate AC measurement: it works for low- and high-frequency currents without altering the circuit.
  3. Electrical system monitoring: it is used in energy meters, protection and control systems, and power quality analysis.
  4. Measurement without interruptions: it has no solid magnetic core and encircles the conductor, so it is placed around the cable without disconnecting anything. This is more convenient and safer in industrial environments.
  5. Research and diagnostics: it is used in laboratories and in electrical equipment testing because of its high accuracy and its ability to measure currents continuously.

Advantages of Rogowski probes

  • Non-invasive: it does not require disconnecting the circuit or modifying the installation.
  • High accuracy: it measures currents accurately, even under high-frequency conditions.
  • Flexibility: it adapts to a wide range of conductor sizes and to hard-to-reach places.

Specifications

Model RCP500
Bandwidth (-3dB)
Range 200mApk-500Apk
Output connector Powered BNC/external BNC
Output sensitivity 10mV/A
Typical accuracy 1%
Phase accuracy (45Hz-66Hz)
Temperature coefficient temperature range + 0.05 × accuracy specifications /℃ (23℃±5℃)
Conductor position accuracy Within ±1% (deviation from center)
Influence of external magnetic fields 1.5% fs or less (400 A/m, 50 Hz/60 Hz)
Withstand voltage ±1mV or less
Maximum voltage AC 10 kV RMS (1 minute), (50 Hz/60 Hz) (Rogowski coil only)
Output impedance High resistance
Output noise <2mv rms
Maximum conductor diameter ≤Φ50mm
Power supply DC 5V
Cable length from coil to integrator 2m
Dimensions 37*22*82mm
Rogowski coil inner diameter 50 mm
Rogowski coil thickness Ø6mm
Environmental characteristics
Operating temperature -20-70℃
Storage temperature -30℃-70℃
Operating humidity Max 80%, non-condensing
Operating altitude ≤2000 m
Operating environment Indoor use, grade 2.
We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer