Power quality analysis course in Monterrey

Hands-on course to identify power quality parameters, with real field tests and a DC-3 certificate from the STPS.

Power quality analysis course in Monterrey

Learn to identify power quality parameters

We have qualified instructors to train your personnel in-house. We hold registrations with the STPS that allow us to issue the Mexican DC-3 labor skills certificate at the end of each training course, as well as certificates valid before State and Municipal Civil Protection (Nuevo León).

All courses are taught by instructors certified in andragogical methodology, which focuses on adult education. The topic depends on the students present: each course is different, and the time devoted to each parameter depends on their needs. We place the emphasis on understanding and provide tools so that students can apply what they know and learn. The student participates, just as the instructor does.

Electrical fundamentals must be understood before moving on to specific details. Installations, electrical safety, grounding and equipotential bonding are covered extensively, because most quality problems are caused by them.

Days before the course we provide PowerPoint presentations and PDFs, a feedback form on each student’s expectations and instructions for participating. The courses include real field tests, not typical simulations.

Advantages

  • Course tailored to your organization’s needs.
  • Location and schedule to suit your work system.
  • Attention to specific questions and problems.
  • Curricular credits, with the possibility of earning a specialization.
  • Issuance of the DC-3 form of the Secretaría del Trabajo y Previsión Social (STPS).
  • Possibility of certifying your competencies.
  • Instructors active in the field, with experience in high-risk areas (platforms, mining, refineries, etc.).

Our YouTube channel: www.youtube.com/user/electronicatutorial

Syllabus: power quality

Power quality is the study of electric power systems that show disturbances and distortion of the voltage and current waveforms, caused by nonlinear loads or power electronic devices.

These devices have improved industrial and, in some cases, commercial processes. In return, they pollute the electrical system and affect power quality and installations. This pollution is due to voltage and current harmonics, voltage unbalance, transient overvoltages, frequency variations and other disturbances.

These disturbances must be measured with instruments, equipment or power analyzers that comply with standard methods and procedures, and the measured values must comply with defined standards.

The course methodology makes it possible to measure power quality with any power analyzer that has the characteristics required by the standards. It is used to perform tests to understand and analyze the disturbances affecting the system under analysis, both at commercial boundaries and in the operation of a particular piece of equipment. Many of the measurement techniques are defined by the IEC 61000-4 series of standards and by IEEE 519.

Power quality studies, measurements and practices require a working methodology guided by international norms and standards. We have a power analyzer for experimental exercises that familiarize engineers with the handling of the instrument. The problem is approached with inspection forms focused on the analysis of power quality events. Power analyzers determine power quality parameters, so basic knowledge in this field is required.

We do real tests, on video! Watch them on our YouTube channel →