Current and differential oscilloscope probes
We rent AC/DC current probes, flexible and rigid probes and high-voltage differential oscilloscope probes in different current ranges, bandwidths and frequencies. We work with brands such as Tektronix, Keysight, Agilent, LeCroy, Fluke and Hantek for current, differential voltage and waveform measurements in power electronics, power supplies, motors, inverters, converters and electronic systems.
We have equipment in stock for immediate delivery, subject to availability. We offer sale and rental of new and used measuring equipment and accessories for customers throughout Mexico.
Current probes
A current probe measures current indirectly and converts it into a proportional voltage signal that the oscilloscope can interpret. This displays the current waveform, including direct current, alternating current, transients, peaks and switching events.
Depending on the probe type, the measurement is AC, DC or AC/DC, with different current capacities and bandwidths. By combining the current with the oscilloscope’s voltage measurements, you can also analyze instantaneous power, losses, consumption, efficiency and the behavior of power devices.
We have models such as the Tektronix TCP202, Fluke iFlex, flexible or rigid current probes and Hantek CC-65, as well as other alternatives depending on the application and the measurement range.
Tektronix TCP202
Current probe for measuring AC and DC current with compatible oscilloscopes. Its bandwidth makes it possible to analyze high-speed signals and transient phenomena in electronic circuits.
Main features
- AC/DC current measurement.
- Bandwidth up to 50 MHz.
- Measurement of up to 15 A DC + AC peak current, under the conditions specified by the manufacturer.
- Pulse currents up to 50 A peak.
- Interface compatible with Tektronix measurement systems.
Applications
- Power supplies.
- Electronic converters.
- Inverters.
- Electronic ballasts.
- Power electronics.
- Control systems.
- Device consumption analysis.
- Electronic equipment and avionics systems.
- Circuit development and debugging.
Hantek CC-65
AC/DC current transducer that extends the measurement capabilities of an oscilloscope or multimeter. It converts the conductor current into a proportional electrical signal that is analyzed with conventional instruments.
Main features
- AC/DC current measurement.
- Bandwidth up to 20 kHz.
- Measurement range up to 65 A DC, depending on operating conditions.
- Hall-effect sensor.
- Output for oscilloscopes through a BNC connection.
- Use with multimeters through an appropriate connection.
Applications
- Power circuit measurement.
- Fault diagnosis and analysis.
- Electronic converters.
- Variable frequency drives.
- Electric motors.
- Power electronics.
- Power supplies.
- Current analysis in electronic circuits.
Differential oscilloscope probes
In addition to current probes, we have differential probes for measuring the voltage between two points in a circuit when a conventional ground-referenced probe is not suitable.
They are important in power electronics, where high voltages or signals floating with respect to ground may be present. Depending on the model, they are used to analyze signals in converters, inverters, switching power supplies, motors, DC buses and other power systems.
Which probe you need
The choice depends on the maximum current, signal frequency, type of current (AC/DC), bandwidth, sensitivity and application. Before requesting a rental, please tell us:
- Maximum expected current.
- Minimum current you need to detect.
- AC, DC or AC/DC.
- Operating frequency.
- Required bandwidth.
- Oscilloscope model.
- Type of application.
- Whether you need to measure current or differential voltage.
With this information, we will help you select a probe compatible with your measurement system.
Probe rental and sale
Current and differential probes are available for rent or sale, from manufacturers such as Tektronix, Keysight, Agilent, LeCroy, Fluke and Hantek. We have equipment in stock for immediate delivery, subject to availability, and we ship throughout Mexico.
Request availability and a quote for the probe you need for your oscilloscope.