NESLAB GP-300 Heating Bath Rental in Monterrey

Temperature-controlled bath for thermal immersion testing in laboratory work, research, development and engineering, with the sample submerged in a heated fluid.

Laboratory heating bath for fluid immersion testing

Temperature-controlled bath for immersion testing

The NESLAB GP-300 is a heating bath for laboratory work, research, development and engineering tests that require heating a fluid and holding it at a set temperature. Unlike an environmental chamber, it allows the sample, component or material to be placed directly in the fluid, with more direct and uniform thermal contact.

It is useful when the part must remain fully submerged in a liquid at a controlled temperature for a set period: thermal tests, materials characterization, evaluation of electronic components and repeatable experimental tests.

Temperature range

It is intended for heating and operates from approximately ambient +5 °C up to +150 °C, depending on the operating conditions and the fluid. In specific configurations it can reach up to +200 °C, depending on the heating element and the exact equipment configuration.

This makes it possible to raise the temperature of a sample gradually or hold it at a stable thermal condition for a set period.

Fluid immersion testing

Heat is transferred directly through the bath fluid. The sample is placed in the thermal medium and held at the selected temperature. It is useful for:

  • Electronic components.
  • Circuit boards and electronic devices, when the fluid is compatible.
  • Materials and polymers.
  • Seals and gaskets.
  • Sensors.
  • Mechanical components.
  • Materials for industrial applications.
  • Thermal stability tests.
  • Prototype research and development.

The fluid is selected according to the test temperature, chemical compatibility and the characteristics of the material under evaluation.

Controlled heating

The GP-300 has a heating system that raises the bath temperature and holds it around the setpoint. It allows more controlled thermal testing than a conventional heat source, and it is appropriate when the goal is to hold the sample at a defined thermal condition for a period of time.

Laboratory and engineering applications

The rental NESLAB GP-300 is used in research, development and validation, especially when an environmental chamber is not the right solution:

  • Thermal immersion tests.
  • Materials characterization.
  • Evaluation of electronic components.
  • Thermal aging tests.
  • Evaluation of polymeric materials.
  • Stability tests at elevated temperature.
  • Product research and development.
  • Prototype validation.
  • Laboratory tests.
  • Heat transfer tests.
  • Evaluation of sensors and components.

NESLAB GP-300 vs. an environmental chamber

An environmental chamber mainly controls the temperature of the air around the sample. The NESLAB GP-300 is a thermal bath: the sample is in direct contact with a temperature-controlled fluid.

If you need to keep a component submerged for several hours at a set temperature, a temperature bath may be more appropriate than an environmental chamber.

Main specifications

Feature NESLAB GP-300
Equipment type Heating bath
Main application Heating and temperature control
Test method Fluid immersion
Minimum operating temperature Approximately ambient +5 °C
Typical maximum temperature +150 °C
Maximum temperature depending on configuration Up to +200 °C
Bath capacity Approximately 20 L
Heating power Approximately 1,200 W
Applications Laboratory, R&D, thermal testing and immersion

Note: the maximum range depends on the equipment configuration, the heating element and the fluid. For high temperatures, use a fluid compatible with the test temperature.

Rental in Monterrey

Renting the NESLAB GP-300 in Monterrey gives you access to a temperature-controlled bath without the investment of owning one. It is an option for companies, laboratories, universities, research centers and engineers who need thermal immersion testing for a set period.

We help you determine whether the GP-300 is suitable for your application and choose the test conditions.

Check availability

Tell us the test temperature, the test duration, the sample dimensions and the type of fluid you want to use. With that information we define the right configuration.