Electric and magnetic fields on lines, substations and industrial facilities
We measure and evaluate low-frequency (ELF) electromagnetic fields associated with transmission and distribution lines, substations, transformers, motors, electrical panels and other equipment operating at 50 or 60 Hz.
We use the professional Holaday HI-3604 meter, designed to evaluate electric and magnetic fields generated by power systems and electrical equipment in operation.
The measurements characterize the electromagnetic environment of a facility, identify spatial variations in the fields and provide technical information for exposure studies, safety evaluations and documentation of site conditions.
Request a quote to measure electromagnetic fields at your facility.
What the Holaday HI-3604 measures
It is an instrument for measuring electric and magnetic fields associated with the power supply frequency. It has selectable sensors for both types of field.
Electric field (E)
It evaluates the strength of the electric field generated by the potential differences between energized conductors and their surroundings.
- Unit of measurement: volts per meter (V/m).
- Applications: transmission lines, substations, electrical installations and energized equipment.
- Range stated in the manual: 1 V/m to 199 kV/m.
Magnetic field (B)
It evaluates the magnetic flux density produced by the currents flowing through conductors and equipment.
- Units of measurement: microtesla (µT), nanotesla (nT), milligauss (mG) and gauss (G), depending on the configuration.
- Applications: power lines, transformers, motors, panels and power conductors.
- Range stated in the manual: 0.1 mG to 20 G.
The instrument uses true RMS detection and responds to 50/60 Hz and to the first harmonics of the supply frequency. The effective response depends on the amplitude, the selected range and the characteristics of the signal.
The instrument measures electric or magnetic field according to the selected mode, not both at the same time.
Service applications
Electrical transmission and distribution lines
We measure at selected points around overhead transmission and distribution lines to characterize the surrounding electric and magnetic fields. The study can include lateral profiles relative to the line axis, measurements at different distances and heights, and identification of the points of highest field strength within the evaluated area.
Electrical substations
We evaluate power-frequency fields near power transformers, busbars, conductors, switchgear and other electrical installations. The measurements document the electromagnetic conditions at the accessible points defined within the scope of the study.
Transformers and electrical equipment
We characterize the magnetic fields around transformers, motors, generators, distribution panels and other equipment that carries or uses alternating current. The results are useful for comparing locations, identifying spatial gradients and documenting field behavior under different operating conditions.
Industrial facilities and buildings
We evaluate low-frequency fields in industrial plants, electrical rooms, control centers, commercial facilities and buildings near electrical infrastructure. The service helps investigate the presence of fields and how they vary with location and with the operating conditions of the equipment.
Electromagnetic field exposure studies
The measurements can form part of technical evaluations of occupational or environmental exposure to power-frequency electric and magnetic fields. Interpreting the results requires establishing the applicable reference criterion, considering the exposure conditions and documenting the limitations of the measurement. Use of the HI-3604 does not, in itself, imply certification of regulatory compliance.
How we perform the measurements
Our procedure is adapted to each facility and to the objectives of the study.
- Site inspection. We identify the relevant electrical sources, the areas of interest and the operating conditions during the measurements.
- Definition of measurement points. We establish locations, heights and distances that characterize the field in the evaluated area.
- Electric and magnetic field measurement. We use the Holaday HI-3604 to record the quantities, with the appropriate measurement mode and sensor orientation.
- Recording of test conditions. We document locations, known operating conditions, units, readings and any condition that may influence the results.
- Analysis and reporting. We organize the results to compare points and interpret them according to the agreed technical or regulatory criteria.
Equipment for low-frequency measurements
The Holaday HI-3604 is designed for studies of fields associated with electric power systems. Its features:
- Selectable sensors for electric and magnetic fields.
- Digital field strength readout.
- True RMS detection.
- Automatic range selection.
- Maximum reading hold function.
- Internal memory to record up to 112 readings.
- Signal output for observing the waveform with appropriate instrumentation.
- Remote readout with the HI-3616 fiber-optic accessory, when available.
For electric field measurements, it is best to mount the instrument on a non-conductive support and keep the operator at a distance, to reduce disturbances caused by the human body. The procedure must follow the manufacturer’s safety and operating instructions.
Standards and evaluation criteria
Depending on the purpose of the study and the type of installation, these technical references may be considered:
- IEEE Std 644: procedures for measuring power-frequency electric and magnetic fields associated with transmission lines.
- IEC 61786-1 and IEC 61786-2: requirements and methods for measuring low-frequency electric and magnetic fields with regard to human exposure.
- ICNIRP: guidelines for evaluating exposure to low-frequency electric and magnetic fields.
- Applicable Mexican regulations: determined by the activity, the measurement location and the purpose of the study.
The criterion must be selected before the evaluation. The applicability of each reference, its limits and its measurement requirements must be verified for each case.
Service deliverables
The scope of the report is defined with the client and may include:
- Identification of the measurement points.
- Description of the operating conditions observed or provided.
- Electric field results in V/m.
- Magnetic field results in µT, nT or equivalent units.
- Comparative tables and, where applicable, spatial measurement profiles.
- Photographic evidence of the evaluated locations.
- Technical references used for interpretation.
- Observations and conclusions limited to the scope of the study.
Measurement uncertainty and metrological traceability are documented when they are part of the contracted scope and sufficient information exists to support them.
Frequently asked questions
Can the Holaday HI-3604 measure fields near high-voltage lines?
Yes. The instrument was designed to evaluate electric and magnetic fields associated with transmission and distribution lines. Measurements must be made from safe positions, without approaching energized conductors or encroaching on safety distances.
Can it measure fields from transformers and motors?
Yes. It can characterize power-frequency fields around transformers, motors, generators and other electrical equipment, provided that the signal and its amplitude are within the capabilities of the instrument.
Does it measure electric and magnetic fields at the same time?
No. The HI-3604 has selectable modes for electric or magnetic field. To obtain both results, a measurement is made in each mode.
Can the measurements determine whether a facility complies with regulations?
The results can be compared with applicable reference criteria. A conclusion of compliance depends on the selected standard, the procedure used, the exposure conditions and the metrological validity of the results.
Does the service include electrical tests on the transmission line?
No. This service evaluates the electric and magnetic fields around the installation. It does not replace insulation tests, voltage or current measurements, power quality analysis or direct electrical testing.
Request a quote
We help you define a low-frequency electromagnetic field study for transmission lines, substations, transformers, industrial facilities and other electrical equipment. Tell us the location, type of installation, operating frequency and purpose of the evaluation, so that we can define the measurement points and the scope of the technical report.