Insulating Oil Tan Delta and Resistivity Tester

Portable, fully automatic dielectric loss and resistivity tester for insulating oil, designed in accordance with ASTM D924 and GB/5654. For laboratories and those responsible for transformer maintenance.

Description

The insulating oil dielectric loss tester (tan delta tester) is a new-generation, portable, fully automatic resistivity and dielectric loss tester. It is designed in accordance with ASTM D924 and GB/5654. It measures the dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. It is easy to operate and delivers reliable, accurate test data.

The instrument has an integrated structure. It combines the dielectric loss cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test source, standard capacitor, high-resistance meter and DC high-voltage source, among other main components. It has a large LCD screen. Results are stored and printed automatically, so an operator with no professional training can use it with ease.

Features

  1. The cup complies with the national standard GB / T5654-2007. It has a three-electrode structure and a 2 mm electrode gap. It eliminates the effects of stray capacitance and leakage on dielectric loss results.
  2. It uses medium-frequency induction heating and PID temperature control. The oil cup and the heating body have no contact; heating is uniform and fast, and temperature control is tight.
  3. The internal standard capacitor is filled with SF6 gas. Its three-electrode capacitance and electrical capacity are independent of ambient temperature, humidity and other effects. The instrument’s accuracy is maintained even after prolonged use.
  4. The AC test source uses AC-DC-AC conversion to avoid fluctuations in the mains voltage and the effect of frequency on the dielectric loss measurement. The instrument works correctly even on a generator.
  5. Full protection. In the event of overvoltage, overcurrent or a high-voltage short circuit, the instrument quickly cuts the high voltage and issues a warning message. It also warns when the temperature sensor fails or is not connected.
  6. The medium-frequency induction heating furnace has a temperature limit relay. When the temperature exceeds 120 degrees, the instrument releases the relay and stops heating.
  7. Configurable test parameters: temperature of 0 ~ 125 ℃, AC voltage of 500 ~ 2200V and DC voltage of 0 ~ 500V.
  8. Large backlit LCD screen and user-friendly interface. You enter the commands and the instrument tests, stores and prints the results automatically.
  9. Built-in real-time clock. The test date and time are kept with the results and can be displayed and printed.
  10. Air electrode cup calibration function. It measures the cup’s capacitance and dielectric loss factor to determine its cleanliness and assembly condition. The calibration data are saved automatically to facilitate calculation of relative permittivity and DC resistivity.

In our laboratory we also perform these tests for your transformers.