Calibration of pressure instruments and process calibrators in Monterrey

Calibration and verification of pneumatic and hydraulic pumps, Fluke pressure sensors and modules, and process calibrators. For plants, laboratories and maintenance companies.

Calibration of pressure instruments and process calibrators in the laboratory

Calibration of pressure instruments and industrial processes

At Creativeit we calibrate pressure instruments and process calibrators used in the process industries, manufacturing, energy, oil and gas, food, pharmaceuticals, mining and industrial automation. We verify the performance and accuracy of equipment that generates, measures and simulates pressure and instrumentation signals, with traceable results.

Our procedures evaluate the precision, repeatability, linearity and measurement uncertainty of each instrument, in accordance with the requirements of national and international standards.

Calibration of pneumatic pumps

We calibrate and verify pneumatic pumps that generate pressure and vacuum in laboratories and industrial maintenance.

Common equipment

  • Manual pneumatic pumps
  • Vacuum pumps
  • Precision pressure generators
  • Pumps for transmitter calibration
  • Pumps for pressure gauge calibration
  • Pumps for pressure switch calibration

Typical ranges

  • Vacuum
  • Low pressure
  • Positive pressure
  • Differential pressure

Calibration of hydraulic pumps

We calibrate hydraulic pumps used in high-pressure testing and in the calibration of industrial instruments.

Applications

  • Hydraulic pressure gauges
  • Pressure transmitters
  • Digital indicators
  • Pressure switches
  • Industrial hydraulic systems

We work with equipment that generates pressures from a few bar up to thousands of psi, depending on the instrument model.

Calibration of Fluke pressure sensors and modules

We calibrate and verify smart pressure sensors used with process calibrators, including:

  • Fluke 700P Series
  • Fluke PM200
  • Fluke PM500
  • Absolute pressure sensors
  • Gauge pressure sensors
  • Differential pressure sensors
  • Vacuum sensors

We perform tests of:

  • Accuracy
  • Hysteresis
  • Repeatability
  • Linearity
  • Maximum permissible error
  • Stability

Differential pressure calibration

Differential pressure is one of the most important variables in industrial processes and HVAC systems. We calibrate instruments used in:

  • Cleanrooms
  • HEPA filters
  • HVAC systems
  • Laminar flow cabinets
  • Industrial filter monitoring
  • Pharmaceutical processes
  • Food processes

Calibration of process calibrators

We also verify and calibrate multifunction calibrators for maintenance, instrumentation and automation. The most common include:

  • Fluke 754 Documenting Process Calibrator
  • Fluke 753
  • Fluke 789 ProcessMeter
  • Fluke 787
  • Fluke 725
  • Fluke 726
  • Fluke 724
  • Fluke 707
  • Fluke 705
  • Fluke 709H
  • Beamex
  • Druck
  • Additel
  • Martel
  • Meriam

Variables we calibrate

  • Pressure
  • Vacuum
  • Differential pressure
  • 4–20 mA current
  • DC voltage
  • Frequency
  • Pulses
  • Thermocouples (J, K, T, E, R, S, B, N)
  • RTD Pt100, Pt1000
  • Resistance
  • Process signals
  • Smart transmitters

Reference standards

We calibrate with high-precision measurement standards and reference equipment with metrological traceability, for industrial and quality assurance applications.

Sectors

  • Automotive industry
  • Petrochemicals
  • Oil & Gas
  • Power generation
  • Manufacturing
  • Food industry
  • Pharmaceutical industry
  • HVAC
  • Water treatment
  • Calibration laboratories
  • Industrial maintenance companies

Benefits

  • Calibration with metrological traceability.
  • Procedures in accordance with international standards.
  • Complete verification of instrument performance.
  • Detailed technical reports.
  • Service in our laboratory or on site.
  • Support for preventive maintenance programs and quality management systems.

We calibrate pneumatic and hydraulic pumps, pressure sensors, differential modules and multifunction process calibrators for industries and laboratories that require precise, repeatable measurements.

We do real tests, on video! Watch them on our YouTube channel →