Hipot Dielectric Testing of Hot Sticks, Aerial Buckets and Gloves in Monterrey

Testing and calibration of hot sticks and other dielectric equipment with hipot up to 140kV, in the field or in the laboratory, for line crews.

Electrical hipot testing of hot sticks, aerial buckets and dielectric gloves

Dielectric hot stick testing and calibration

We provide certification services for hot sticks and other dielectric equipment with hipot up to 140kV. The safety of line crews is crucial and depends on the condition of the equipment they use. We perform the tests in the field or in the laboratory.

Hot stick calibrations support your organization’s efforts to ensure tool safety. Our aim is for your line crews to be alerted to the presence of voltage and to avoid dangerous exposure. Calibration confirms that a basic hot stick or a hot stick voltage detector still meets the manufacturer’s specifications, even after demanding field work.

Where applicable, our services can help you comply with the testing phase of the OSHA regulation, which requires the hot stick to be examined, cleaned, repaired and tested every two years.

Hot stick testers and voltage detectors

Voltage detectors can be mounted on a suitable hot stick when crews need to detect energized lines without contact. Our calibrations determine whether the equipment is working correctly. We offer laboratory services and testing at the customer’s facilities for electrical detection tools. If your periodic inspections uncover defects, we can calibrate the equipment after repair.

OSHA requirements

We service hot sticks of different lengths and designs. Our laboratory offers:

  • Tests tailored to your hot stick and its applications, performed by trained technicians.
  • Videos and photographs of the measurements, for greater customer assurance.
  • Calibrations of hot sticks with built-in voltage detectors.
  • Service for most hot stick makes and models, including Hastings, Amprobe, AEMC, Salisbury and more.
  • High-voltage testing to verify that a hot stick meets OSHA guidelines: 75,000 volts for one minute along each foot of wet hot stick, or 100,000 volts dry.

After calibration you will know whether your hot stick meets your requirements, whether those are manufacturer’s specifications, internal standards or government regulations.

We do real tests, on video! Watch them on our YouTube channel →