High-Voltage Insulation Resistance Tester (Megohmmeter)

Digital insulation resistance tester, also called a megohmmeter, for laboratory or on-site testing. Measures insulation in transformers, motors, cables and electrical equipment.

Description

The insulation resistance tester, also known as a megohmmeter, high-voltage megohmmeter or high-voltage insulation resistance tester, is used specifically for insulation testing in the laboratory or on site.

It is used to measure the resistance value of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment. The digital meter is built with medium- and large-scale integrated circuits, and includes a high-precision microcurrent measuring system, a digital step-up system and an automatic discharge circuit. You only need to connect the DUT with a high-voltage line and a signal line to measure.

  • Rated output test voltage range: 250 V ~ 5000 V.
  • Insulation resistance measuring range: 0.01 MΩ ~ 5.00 TΩ.
  • DC voltage measuring range: 0 V ~ 1000 V DC.
  • AC voltage measuring range: 0 V ~ 750 V AC.

Technical specifications

Insulation resistance measuring range and accuracy

Output voltage Measuring range Accuracy
250V ( 15% ) DC 0.01MΩ~2.50GΩ ±3%rdg±5dgt
250V ( 15% ) DC 2.50GΩ~250 G Ω ±15%rdg±5dgt
500V ( 10% ) DC 0.01MΩ~5.00GΩ ±3%rdg±5dgt
1000V ( 10% ) DC 0.01MΩ~10.00GΩ ±3%rdg±5dgt
1000V ( 10% ) DC 10.00GΩ~1.00 T Ω ±15%rdg±5dgt
2500V ( 10% ) DC 0.01MΩ~25.0GΩ ±3%rdg±5dgt
2500V ( 10% ) DC 25.0GΩ~2.50 T Ω ±15%rdg±5dgt
5000V ( 10% ) DC 0.01MΩ~50.0GΩ ±3%rdg±5dgt
5000V ( 10% ) DC 50.0GΩ~5.00 T Ω ±15%rdg±5dgt

AC and DC voltage range and accuracy

Measured voltage Measuring range Accuracy
AC voltage 0.01V~750V ±2%rdg±3dgt
DC voltage 0.01V~1000V ±2%rdg±3dgt

Instrument parts

  1. LCD
  2. LINE terminal
  3. GUARD terminal
  4. EARTH terminal
  5. V voltage test terminal
  6. Function button
  7. Test key and test indicator light
  8. Rotary platform switch
  9. USB interface
  10. Charging port
  11. High-voltage rod port
  12. High-voltage rod
  13. High-voltage rod clip
  14. High-voltage rod hook
  15. High-voltage rod lead wire
  16. Test lead clamp
  17. Test lead