We have medium- and high-voltage detectors for rent. Immediate delivery in the Monterrey metropolitan area and in other cities and states of Mexico.
Super Tester voltage detector
Dual range. Audible and visible indicators.
Features and applications
- The lights flash and the alarm sounds when it is placed in an electrostatic field above the activation threshold.
- Five flashing red lights alert the operator.
- High-pitched tones also alert nearby personnel to the presence of potentially dangerous voltage, for example when applying temporary grounds or during maintenance.
- It can be used to check overhead lines, in substations and around control substations.
- It slides over the head of a standard 1-1⁄4″ diameter disconnect stick.
- It can be used on a universal CHANCE Grip-All clamp hot stick, or on a telescoping or positive-grip live-line hot stick fitted with a special adapter.
Phase-to-phase versus response distance
| Phase to phase (kV) | Distance in inches (Range 1 – 100kV) | Distance in inches (Range 100 – 800kV) |
|---|---|---|
| 2.0 | 0 | – |
| 13.8 | 4 | – |
| 25.0 | 12 | – |
| 34.5 | 19 | 1 |
| 69 | 39 | 3 |
| 115 | – | 7 |
| 161 | – | 10 |
| 230 | – | 20 |
| 345 | – | 26 |
| 525 | – | 44 |
Warning: the instrument is damaged by contact with 33kV or more.
Design features
- The three-way switch selects the 1 – 100 kV range or the 100 – 800 kV range for the circuit under test.
- It switches off to save the battery when not in use.
- The 9-volt alkaline battery is easy to install: remove two thumbscrews and slide off the instrument cover.
- The test button checks the battery and the tester.
- Pressing the button activates the signal circuits: the tone sounds and the alarm lamps light if the battery is good and the unit is working.
- It comes with packed instructions, in a lined, reinforced case with a carrying handle.
Operation
- Switch on the tester with the selector switch on the required voltage range.
- Check the battery and the unit by pressing the “Test” button.
- If the tone volume is not clear or the indicator lights are not bright, replace the battery and check again.
- Mount the tester on the appropriate live-line tool.
Note: Super Tester does not detect voltage in cable with a metallic or semiconducting sheath. It does not distinguish between induced voltage and line voltage: it signals in the presence of either, and the operator must determine which it is before following the electric utility’s safe work practices for attaching to energized conductors.
