Ground Resistance Clamps for Sale (Fluke 1630-2 FC)

We have earth ground testers and ground clamps for sale, in stock for immediate delivery. For engineers and technicians who need to measure grounding resistance without disconnecting the system.

Ground resistance measuring clamps

At Electrónica Monterrey we have a variety of earth ground testers and ground clamps for sale, in stock for immediate delivery. AC leakage current and ground resistance measuring clamps make it possible to identify AC leakage currents without disconnecting the system’s ground stake, which is ideal for troubleshooting.

The clamp’s heavy-duty jaw stays aligned and calibrated even in live industrial environments.

They make it possible to check the grounding of equipment components in hard-to-reach spaces, including indoor or fully paved areas where auxiliary stakes are not allowed. You can identify ground loop resistance without disconnecting the ground electrode from the system and reconnecting it.

The 1630-2 FC stakeless ground resistance clamp is a rugged tool from the Fluke brand. Its jaw stays aligned and calibrated even in live industrial environments.

Measurement logging

The clamp logs data automatically at preset intervals and stores up to 32,760 measurements in memory, at the set logging interval. It saves time by logging and storing measured values.

Alarm threshold

User-defined high and low alarm limits for quick measurement evaluation.

Bandpass filter

The selectable bandpass filter function removes unwanted noise from the AC leakage current.

Stakeless testing

Ground clamps measure ground loop resistances in multi-grounded systems, using the clamp’s double jaw. This technique eliminates the need to disconnect parallel grounds, a dangerous and cumbersome task, and to find suitable locations for auxiliary test stakes. It also makes it possible to check grounding where it was previously difficult: inside buildings, on utility poles or anywhere you cannot reach the soil to place auxiliary test stakes.

What they are used for

Ground measuring clamps verify the grounding resistance of an electrical system. This resistance is crucial for a facility’s grounding system to work correctly and to be able to protect people and equipment in the event of electrical faults.

Main function

They measure the resistance of the ground connection without disconnecting the grounding system or interrupting the operation of the electrical system. This measurement is fundamental for ensuring that the installation has adequate grounding resistance, which should generally be less than 10 ohms to ensure a safe discharge of electric current.

How they work

These clamps are generally used together with a ground tester or ground resistance measuring equipment, and they connect to the grounding system at two points (for example, a ground electrode and the reference system) to measure the resistance at that specific point. Some clamps can also be part of a measuring system that uses alternating current or pulsed current to determine the grounding resistance without direct intervention in the system.

In short, ground measuring clamps make it possible to measure the quality of the ground connection quickly, efficiently and safely, which is essential for maintaining the electrical safety of installations.