Tutorial on FM modulation basics on a spectrum analyzer

A short video on the basics of FM modulation and how its spectral waveform looks on a spectrum analyzer. Includes a review of what the instrument measures and what baseband is.

Video: FM modulation on a spectrum analyzer

Watch the FM modulation video on YouTube

Spectrum analyzer

A spectrum analyzer is an electronic measuring instrument that displays on screen the spectral components, within a frequency spectrum, of the signals present at its input. These can be any type of electrical, acoustic or optical waves.

The vertical axis usually shows, on a logarithmic scale, the level in dBm of the signal’s spectral content. The horizontal axis represents frequency, on a scale that depends on the time separation and the number of samples captured. The analyzer’s center frequency is the one that corresponds to the midpoint of the screen.

It is often used to measure the spectrum of electrical power. It is currently being replaced by the vector signal analyzer.

What the analyzer shows

The spectrum analyzer shows the spectrum of the input signal, that is, its frequency components. A pure sine wave has an amplitude peak at its frequency. A square wave is not a pure sine wave, so it has more frequency components, which are explained by the Fourier series expansion. More complex signals, such as a song, have an approximately continuous spectrum within a given bandwidth.

There are many types of analyzers, but most use three main functions:

  • CENTER FREQUENCY control: indicates the frequency at the center of the display.
  • SPAN: the range of frequencies that appears on screen.
  • AMPLITUDE or INPUT LEVEL: the input reference level. Signals arriving at a lower level are set to a lower amplitude.

Baseband modulation

The term baseband refers to the band of frequencies produced by a transducer, such as a microphone, a telegraph key or another signal generator, that does not need to be adapted to the medium through which it will be transmitted.

Baseband is the signal of a single transmission on a channel. Broadband means that it carries more than one signal, each on a different channel, up to the maximum number of channels.

In transmission systems, baseband is generally used to modulate a carrier. In demodulation, the original baseband signal is reconstructed. Baseband therefore describes the state of the signal before modulation and multiplexing, and after demultiplexing and demodulation.

Baseband frequencies are generally much lower than those that result from using them to modulate a carrier or subcarrier. For example, the composite video output of video recorders or players and game consoles is a baseband signal. Television signals, on the other hand, must be modulated to be carried over the air (free-to-air or satellite) or by cable.