What is a DIAC
The DIAC, or “diode for alternating current”, conducts current only after its breakover voltage, VBO, has been momentarily reached.
When this happens, the diode enters the region of negative dynamic resistance: the voltage drop decreases and the current usually rises sharply. The diode stays in conduction until the current falls below a value characteristic of the device, the holding current, IH. Below that value it returns to its high-resistance (non-conducting) state. The behavior is bidirectional: it is usually the same for both directions of current flow.
Most DIACs have a three-layer structure with a breakover voltage of around 30 V. Their behavior resembles that of a neon lamp, but it is controlled much more precisely and occurs at lower voltages.
DIACs have no gate electrode, unlike other thyristors used for triggering, such as TRIACs. Some TRIACs, such as the Quadrac, include a built-in DIAC in series with the gate terminal for that purpose.
What is a dimmer
Dimmers change the brightness of a light. Lowering or raising the RMS voltage, and with it the average power reaching the lamp, varies the light intensity. Variable-voltage devices serve a number of purposes, but the term dimmer is normally reserved for light control of incandescent, halogen and, more recently, compact fluorescent (CFL) and LED lamps. Dimming fluorescent, mercury vapor, solid-state or arc lighting requires more specialized equipment.
Dimmers range from small units the size of a light switch for indoor lighting to high-power units for large theaters or architectural lighting. Small household dimmers are usually controlled directly, although remote control systems such as X10 exist. Modern professional dimmers usually operate with a digital control system such as DMX or DALI. In newer systems, these protocols are often used together with Ethernet.
What is a TRIAC
The TRIAC, or Triode for Alternating Current, is a semiconductor device in the thyristor family. The difference from a conventional thyristor is that the thyristor is unidirectional and the TRIAC is bidirectional. In simple terms, the TRIAC is a switch capable of switching alternating current.
Its internal structure resembles that of two SCRs connected in opposite directions.
It has three electrodes: A1, A2 (which here lose the names anode and cathode) and gate. The TRIAC is triggered by applying a current to the gate electrode.
Video
https://www.youtube.com/watch?v=GWUqOnb7UAA
Watch the video on YouTube (length 7:07)