Dielectric oil breakdown test machines for sale

We stock oil breakdown test machines, with immediate delivery in most cases. For substations, power generation plants, oil laboratories and transformer manufacturers.

Dielectric oil breakdown test machine

The dielectric breakdown voltage test measures the electrical stress an insulating oil can withstand without breaking down.

The equipment is used mainly by service contractors (substations and power generation plants), oil testing laboratories, oil companies, transformer manufacturers and oil quality control departments.

Features

  • Dimensions: 460 mm x 380 mm x 360 mm
  • Weight: 38 kg

What’s in the box

  • Insulating oil tester
  • Power cord
  • Grounding lead
  • Test vessel
  • Mushroom, flat and spherical electrodes, 3 pairs
  • Gap gauge 1mm, 2mm, 2.5mm, 4mm, 4 units
  • Insulating cover
  • Stirrer, 2 units
  • Insulating adhesive
  • High-voltage column
  • USB-RS232 connection line
  • Thermal printer paper
  • Fuse (5A / 3A), 2 units / 2 units
  • Instruction manual
  • Disc
  • Inspection report
  • Quality certificate

Technical specifications

  • Range: AC output voltage 0V~100KV
  • Voltage rise rate: 0.5kv/s±10%, 2kv/s±5%, 3kv/s±5%, 5kv/s±5%
  • Temperature: 0°C to 70°C
  • Tolerances: ±(1% full scale + 2 digits). Resolution: 0.1KV
  • Temperature resolution: 1°C

Why check the dielectric strength of oil

Checking the dielectric strength of transformer oil is an essential condition for ensuring the reliable operation of power transformers.

The dielectric strength test is one of the main tests for determining the insulating properties of oil under extreme voltage. Dielectric strength must be higher than the threshold value. It can be reduced by contaminants such as water, sediment, various acids and conductive particles. Weakened dielectric strength produces leakage current between the HV and LV windings and, in some cases, sparks or short circuits. Clean, dry oil is a sign of purity, but does not by itself confirm the absence of contaminants.

Oil breakdown meter

An oil breakdown meter is a device for testing an oil sample in a test cell with electrodes. After testing the oil and its breakdown point, you can estimate whether the oil has aged because of higher water content, sludge or excessive oxidation, or whether it is in its original condition.

The most widely used type is the insulating oil tester, designed to determine easily and accurately the dielectric strength of insulating oils in electrical apparatus such as transformers. It is suitable for on-site testing and for laboratory use. The most common field test, checking the dielectric strength of the oil, must be carried out in accordance with the requirements of BS 5874.

Standards

There are several types and models of oil testers. Models able to measure dielectric breakdown voltage must go up to 100 kV to determine the dielectric strength of the oil. In addition, there are several standards for the electrical devices used to measure the strength of the oil under test.

We do real tests, on video! Watch them on our YouTube channel →