CT/PT Transformer Tester with Frequency Conversion for Sale

Test instrument for current transformers (CT) and potential transformers (PT) in the power industry. Measures excitation, ratio, polarity and more.

Description

The equipment uses a high-performance DSP and ARM for stable operation. It has complete functions, a high degree of automation and high test efficiency. It is a professional test instrument for transformers in the power industry.

Features and functions

  • Tests the excitation (volt-ampere) characteristic, turns ratio, polarity, secondary winding resistance, secondary burden, ratio difference and angle difference of various CTs (protection, metering, TP). It also tests the excitation, turns ratio, polarity, secondary winding resistance, ratio difference and angle difference of electromagnetic PT units.
  • Obtains the knee-point voltage and current, the 10% (5%) error curve, the accuracy limit factor (ALF), the instrument security factor (FS), the secondary time constant (Ts), the remanence factor (Kr), saturation, and CT and PT parameters such as unsaturated inductance.
  • Testing follows several transformer standards, such as GB1208 (IEC60044-1), GB16847 (IEC60044-6) and GB1207. The equipment automatically selects the standard according to the transformer type and class.
  • It is based on the low-frequency (frequency conversion) method and can test CTs with a high knee point.
  • The graphical interface is in Chinese.
  • It saves test data sets that are not lost after a power outage. When the test is finished, save the data to the PC with a USB flash drive, analyze it with the software and generate a WORD report.
  • Testing is simple. CT DC resistance, excitation, turns ratio and polarity are completed with one key. Except for the burden test, all other CT tests use the same wiring.
  • It is easy to transport: it weighs <9Kg.

Technical specifications

Test object Protection class CT, protection class PT
Output 0~180Vrms, 12Arms, 18 A (Peak)
CT ratio measurement: range 1~40000
CT ratio measurement: accuracy ±0.05%
PT ratio measurement: range 1~40000
PT ratio measurement: accuracy ±0.05%
Phase measurement: accuracy ±5min
Phase measurement: resolution 0.5min
AC burden measurement: range 0~300Ω
AC burden measurement: accuracy 2%±2mΩ
AC burden measurement: range 0~1000VA
AC burden measurement: accuracy 2%±0.2VA
Input supply voltage AC220V±10%, 50Hz
Working environment Temperature: -10 °C ~ 50 °C; humidity: ≤90%
Size and weight 340mm x 300mm x 150mm; weight <9kg

Tests performed

CT performance test

The volt-ampere curve automatically gives the knee-point value (class P) and the 5 percent/10 percent curve (class P). It also gives the turns ratio, ratio difference, phase (angle difference), polarity, primary current, AC withstand voltage, secondary burden, secondary winding DC resistance and core demagnetization.

PT performance test

The volt-ampere curve automatically gives the knee-point value, turns ratio, ratio difference, phase (angle difference), polarity, AC withstand voltage and secondary burden.

Volt-ampere characteristic curve (excitation characteristic)

It is generally used only for the protection winding.

  • It can reflect the quality of the transformer’s iron core, calculate the knee-point voltage and analyze performance with the original data.
  • It can also reflect whether there is an inter-turn short circuit.
  • With the voltage and current data for each point, it draws the error curve of the CT protection winding to determine whether the protection requirements are met.

On-site verification and other functions

  • On-site verification of current transformers does not require standard current transformers, current amplifiers, burden boxes, voltage regulator control boxes or high-current cables. CT polarity, excitation, turns ratio and DC resistance tests are completed with a single key. Except for the burden test, all other CT tests use the same wiring. This reduces the workload and improves efficiency.
  • It also measures the ratio difference and angle difference. The maximum permissible error of the ratio difference is ±0.1 percent and that of the angle difference is ±5min.
  • Using the frequency conversion method, it tests the CT/PT volt-ampere curve and the 10 percent error curve. The maximum output is only 180 V AC and 12 Arms of AC current, and it can still test CTs with a high knee point.
  • It automatically gives the knee-point voltage and current, the 10 percent (5 percent) error curve, the accuracy limit factor (ALF), the instrument security factor (FS), the quadratic time constant (Ts), the remanence coefficient (Kr), saturation, and CT and PT parameters such as saturation inductance.
  • It has a 5.7-inch transflective graphic LCD screen, visible in sunlight, and is operated with a rotary optical mouse. The panel includes a printer that automatically prints the test report. Saved test data are not lost when the equipment is switched off.