Basic multimeter use: continuity, voltage, resistance and current

A tutorial on the basic use of the digital multimeter (polymeter) to measure continuity, voltage, resistance and current. For technicians starting to work with measuring equipment.

Basic multimeter use

Handling measuring equipment is fundamental in electronics, and every good technician must know it thoroughly. In this tutorial we explain the basic use of the multimeter (polymeter) to measure continuity, voltage, resistance and current.

There are many multimeter models on the market, but two large groups stand out: digital and analog. In this tutorial we use a digital multimeter.

Multimeter and polymeter are the same thing: an instrument that measures several parameters. It is not the same as a voltmeter, an ohmmeter or an ammeter, because these measure a single parameter: voltage, resistance or current. The multimeter measures all of them, that is, it is a voltmeter, ohmmeter and ammeter, and it can also include other functions, such as a thermometer.

Safety and reading the manual

To use it correctly, read the manufacturer’s manual carefully and pay special attention to the maximum voltage and current values the multimeter can withstand. This is the safest way to use it, both for the instrument and for the user. Your safety comes first.

Anyone who is not a professional must take special care when handling and checking devices that can produce electric shocks with serious injuries. Always use gloves and insulating material.

Digital or analog multimeter

For accuracy and ease of reading, the digital multimeter is much simpler than the analog one. Its accuracy is defined by the margin of error the manufacturer states in the manual.

With an analog multimeter you have to check the position of the needle on the scale. The user’s skill comes into play, as does parallax error, that is, the deviation of the line of sight if you do not look perpendicular to the scale. Because of its lower price and simplicity, the analog multimeter is a valid option for operators who do not need a professional tool.

Digital meters are the most widely used today, but analog meters have not fallen out of use because they respond quickly (needle movement), something that cannot be detected with digital meters.

The multimeter and its applications

The word multimeter indicates many measurements. With this instrument we can measure AC voltage, DC voltage, AC amperes, DC amperes, resistance, continuity, temperature, frequency and capacitance, as well as the condition of various semiconductors, such as diodes and transistors. There are also multimeters with more options, such as signal generators or an oscilloscope, among others.