What are unconditional amplifier stability and the K factor?

An amplifier is unconditionally stable when it does not oscillate with any passive source or load impedance at a given frequency; the Rollett criterion verifies this with a K factor greater than one together with an S-parameter determinant of magnitude less than one.

Why an amplifier can oscillate

An amplifier with gain always has some internal feedback through its parasitic capacitance. If the impedances it sees at the input and output are such that a negative resistance arises at a port, the reflected signal can be larger than the incident signal and the circuit oscillates. The problem is not only the amplifier, but the amplifier together with whatever is connected to it.

Unconditional and conditional stability

  • Unconditionally stable: with any passive source and load, that is, with reflection coefficients of magnitude less than or equal to one, the device does not oscillate.
  • Conditionally stable: it is stable only for certain source and load impedances. There are passive combinations with which it would oscillate.

The K factor

The Rollett criterion uses the S-parameters of the device at each frequency. It defines a K factor that combines the magnitudes of the reflection and transmission parameters with the determinant of the matrix. The necessary and sufficient condition for unconditional stability is that K be greater than one and the magnitude of the determinant be less than one. There is also an equivalent single-parameter criterion, called mu, which additionally indicates how much margin there is: values greater than one indicate stability.

Stability circles

When the device is conditionally stable, the input and output stability circles are drawn on the Smith chart. They delimit the regions of source and load impedances that cause instability. The designer chooses terminations outside those regions, or adds resistance or feedback to stabilize the device.

What is checked in practice

  1. Calculate K and the determinant across the entire operating band and also outside it, at low and high frequencies. Many amplifiers oscillate at a frequency that was not even of interest.
  2. Check stability with the bias network and external elements included.
  3. Verify with the real amplifier: an unexpected peak in the spectrum, gain that varies when the setup is touched, or output power with no input signal indicate oscillation.

When the K factor is not enough

The criterion is based on small-signal S-parameters. With large signals the operating point changes and stability can vary. In addition, unconditional stability may be achieved at the expense of gain or noise figure, which forces a design trade-off.