How a contact works
Two metal surfaces, however smooth they look, touch only at small asperities. Contact resistance depends on how many real points touch and on what film lies between them. A sufficient normal force breaks through thin films and maintains many conductive points. Anything that reduces that force or increases the film degrades the contact.
Degradation mechanisms
- Plating wear: each insertion and extraction scrapes the plating, normally gold, tin or silver over a copper base. Once the base metal is exposed, it oxidizes.
- Corrosion: moisture, atmospheres containing sulfur or chlorides, and dissimilar metals in contact produce insulating films or galvanic corrosion.
- Fretting: tiny movement, caused by vibration or thermal cycling, wears the plating and forms oxide between the surfaces, particularly on tin contacts. It is a classic cause of intermittent failure.
- Force relaxation: the contact spring loses force through creep at elevated temperature, through overstress from being opened too far, or through repeated insertions.
- Heating: high contact resistance dissipates power, heats the contact, accelerates oxidation and raises the resistance further. The process reinforces itself.
- Contamination and mechanical damage: dust, flux, bent pins and misalignment.
What you see in practice
In low-current signals, degradation shows up as noise, communication errors or faults that disappear when the connector is moved or reinserted. In power circuits there is an abnormal voltage drop across the connector, discoloration of the plastic and, in advanced cases, deformation or burning. With a thermal camera, the damaged contact stands out as a spot hotter than its neighbors carrying the same current.
How to locate the problem
- Compare the voltage drop or resistance between equivalent contacts at operating current, not only with a multimeter at minimal current, which may not break through films.
- Move or press the connector while monitoring the signal to confirm the intermittent fault.
- Inspect under magnification: worn plating, oxide, misaligned pins, arc marks.
- Verify that the materials on both sides are compatible; mixing gold with tin promotes fretting.
When cleaning is not enough
Cleaning with a suitable solvent helps if the problem is contamination. If the plating is already worn or the spring has lost force, the connector must be replaced, because the cause is permanent.