A component with a limited life
An electrolytic capacitor uses a liquid electrolyte and an oxide layer as the dielectric. Unlike other capacitors, it has inherent wear: the electrolyte is gradually lost through evaporation past the seals. As it runs out, the capacitor loses capacitance and its equivalent series resistance increases.
Main causes
- High temperature: accelerates electrolyte evaporation. As a general rule, service life drops markedly with each sustained temperature increase; that is why proximity to heat sinks and poor ventilation shorten its life.
- Ripple current: flows through the ESR and produces internal heating. If it exceeds what the capacitor can withstand, the capacitor overheats.
- Overvoltage: can damage the oxide layer and cause high leakage, gas generation and, in severe cases, rupture of the safety vent.
- Reverse polarity: in polarized capacitors it destroys the oxide and causes rapid failure.
- Manufacturing defects or poor selection: poor-quality electrolytes, or a component chosen with insufficient margins for the application.
How it shows up
- Bulging case, electrolyte leakage or opening of the top vent.
- Excessive ripple at the output of a power supply, spontaneous resets or shutdowns.
- Heating of the capacitor itself.
- Over time, equipment that struggles to start when cold and improves as it warms up, because warm electrolyte conducts better.
How to reduce the risk
Select with margin on voltage and ripple current, place the capacitor away from heat sources, and choose a temperature rating and service life suited to the duty. On equipment with aged capacitors, preventive replacement is usually cheaper than repairing the damage they cause.
Capacitors can retain a dangerous charge; handling must be carried out by qualified personnel in accordance with applicable regulations.