Operating principle
The instrument applies a low-current AC signal to a component and plots current against voltage on a screen. The resulting figure is the component’s “signature”: a resistor gives a straight line, a diode a curve with a knee, an open circuit a horizontal line and a short a vertical line. A capacitor produces an ellipse.
The comparison technique
The most valuable thing is not reading absolute values but comparing. The same terminal is measured on a healthy board and on the defective one, and the differences in the signature are observed. A component in circuit appears combined with everything connected in parallel, which is why comparison between identical boards is so useful: any difference points to the area of the defect.
Advantages
- Testing can be done with the board switched off: the energy applied is very low, which reduces the risk of damaging parts.
- It detects open, shorted or leaky components, even in integrated circuits, by comparing their terminals.
- It does not require knowing the schematic; it works for boards without documentation.
How to interpret the result
- Discharge the board and disconnect it from all power.
- Place one probe on a common reference (ground) and go through the pins with the other.
- Compare the signature with that of the reference board, pin by pin.
- Mark the differences and check those components with another technique.
When it does not apply
It does not test dynamic behavior or behavior at full voltage: a semiconductor can show a good signature and fail in operation. Without a healthy reference, interpretation becomes subjective. And because it is a low-energy sweep, it does not detect defects that only appear at high voltage or with heating.