How is a power semiconductor tested out of circuit?

A power semiconductor is tested out of circuit with the multimeter’s diode mode and, for a more complete check, with a curve tracer that shows its behavior under voltage.

Why out of circuit

In circuit, neighboring components create parallel paths that alter the readings. Removing the semiconductor, or at least isolating its terminals, makes it possible to measure the device alone. The equipment’s capacitors must also be discharged first.

Basic multimeter test

Diode mode applies a small current and displays the forward voltage drop.

  • Diodes and the body diode of a MOSFET: they must conduct in one direction and block in the other. Conducting in both directions indicates a short circuit; conducting in neither, an open circuit.
  • MOSFET: check that there is no short between drain and source or between gate and the other terminals. The gate behaves like a capacitor, so it can stay charged and alter the reading; it should be discharged.
  • IGBTs and bipolar transistors: check the junctions and the absence of a short between collector and emitter.

Limitations of the multimeter

A device can pass this test and still fail. The multimeter applies a small voltage and current, very different from those in operation. It does not detect leakage that only appears at high voltage, a shifted threshold voltage or degraded switching.

More complete verification

A curve tracer applies controlled voltage and current sweeps and displays the characteristic of the device. It makes it possible to check blocking voltage, leakage, gate threshold voltage and on-resistance, comparing them with the datasheet or a known-good sample.

How to interpret the result

A damaged semiconductor almost never fails on its own: the cause usually lies in the gate circuit, the protection or the load. That is why, besides testing it, the gate driver and the protection elements are checked before replacing it.

These tests are done with the equipment de-energized and discharged; work on power equipment must be carried out by qualified personnel in accordance with applicable regulations.