Why temperature gives failures away
A partial short circuit, a high-resistance connection or an overloaded semiconductor dissipates more power than normal and heats up. The opposite is also informative: an area colder than expected may indicate a component that is not conducting. Temperature is an indirect picture of current and power.
Common techniques
- Thermal imaging camera: shows the temperature distribution across a surface and reveals hot spots without contact.
- Thermocouple or contact probe: measures one point with good accuracy, useful for logging changes over time.
- Spot infrared thermometer: fast, but it averages an area, so it can give incorrect readings on small parts.
- Freeze spray: applied locally, it shows whether a component changes its behavior when cooled.
How to measure properly
- Let the equipment reach a stable thermal state before comparing.
- Take the emissivity of the surface into account: shiny metals look colder than they are in an infrared camera.
- Measure under representative load conditions; many defects only heat up under current.
- Compare with a reference: healthy equipment or the same area on a symmetrical component.
- Record the ambient conditions and the exact point measured.
How to interpret the result
A hot spot shows where energy is being dissipated, not necessarily what failed: it may be the culprit component or the victim of an overload coming from elsewhere. It is used to narrow down the area, which is then confirmed with electrical measurements.
Errors that mislead
Reflections of nearby heat sources on shiny surfaces, measurements with the equipment just energized, and taking the case temperature as if it were the internal junction temperature of a semiconductor all lead to false conclusions.
Opening energized equipment to take measurements involves electrical risk; it must be done by qualified personnel in accordance with applicable regulations.