How do you isolate a fault in a circuit by bisection?

Isolating a fault by bisection consists of dividing the circuit into two halves, measuring at the midpoint to find out which half contains the defect, and repeating with that half until it is located.

The idea

If a circuit has a chain of stages, the signal or voltage can be checked at the midpoint. If it is correct there, the fault is further on; if not, it is before that point. Each measurement rules out about half of the circuit, so the number of tests grows very slowly with complexity.

How it is done

  1. Define a known input and an output that should be observed.
  2. Choose an accessible test point near the center of the chain.
  3. Compare what is measured with the expected value, taken from the schematic or from equipment in good condition.
  4. If the value is correct, the defect is downstream; if it is incorrect, upstream.
  5. Repeat on the suspect half until you are left with one stage or one component.

An example in a power supply

If a power supply gives no output, first measure the rectified and filtered voltage on the primary. If it is correct, the problem is in the switching, the transformer or the secondary; the next measurement is then on the secondary winding. Each result reduces the suspect area.

When it works poorly

  • Feedback loops: in a circuit with feedback, a defect at any point alters all the others and the midpoint can be misleading. It is best to open the loop or break it in a controlled way.
  • Inaccessible test points: if the center cannot be measured, choose the nearest point.
  • Multiple or intermittent faults: the binary logic assumes a single stable defect.
  • Loads that drag the signal down: a short circuit downstream can make the signal look bad upstream.

How to interpret the result

Bisection locates the area; it does not confirm the component. Once you reach a small stage, move on to component tests with the circuit de-energized. If circuits with hazardous voltages are measured, this must be done by qualified personnel following the applicable regulations.