24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Permanent magnet or induction motor?

Permanent magnet motors offer higher efficiency and power density, but they depend on rare earth magnets and generate voltage when spinning; induction motors are robust and magnet-free, with lower efficiency at light load.

How they produce torque

In the permanent magnet synchronous motor, the rotor carries magnets that create their own field; the stator creates a rotating field and the rotor follows it in synchronism. In the induction motor, the rotor is a conductive cage without magnets; the stator field induces currents in it and torque arises from that interaction, with a slip between the field speed and the rotor speed.

Differences that matter

  • Efficiency: the magnet motor needs no current to magnetize the rotor and has no losses from rotor currents, so it tends to be more efficient, especially at partial load.
  • Power density: the magnet motor delivers more torque in a smaller size.
  • Materials: high-performance magnets use rare earths, with a dependence on specific supply chains. The induction motor avoids that material.
  • High-speed operation: both require field weakening; in the magnet motor, this is achieved by injecting current that reduces the flux, which adds losses.

The safety difference

A spinning magnet motor generates voltage in its windings even when the inverter is off. If the vehicle is towed or coasts at high speed, that voltage can exceed the bus voltage and requires protection strategies in the inverter. The induction motor, without excitation, generates no voltage when spinning. In addition, the magnet motor carries a small no-load spinning loss, and the magnets can demagnetize with excessive temperature or too high a current.

What is seen on a test bench

When the efficiency map is measured, the magnet motor shows a wider high-efficiency zone; the induction motor maintains a good response at high speed and more tolerant behavior under overloads. Control of the induction motor requires estimating the rotor flux, while the magnet motor needs to know the rotor position precisely.

The choice is a balance of cost, efficiency, supply and control strategy. Work on the traction system is for qualified personnel.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer