What it is for
A real battery is expensive, changes with each cycle and can be dangerous if defective equipment is being tested. An emulator makes it possible to test chargers, DC-DC converters, inverters and other equipment with a source that behaves like a battery, repeatably and safely, and that can represent batteries of different chemistries or states of health.
What sets it apart from a standard power supply
A laboratory power supply regulates a fixed voltage. A battery, by contrast, has an open-circuit voltage that depends on the state of charge and an internal resistance that causes a drop when current flows. An emulator models this: a curve of voltage versus state of charge and a resistance are programmed, and the equipment integrates the current to update the state of charge and adjust the output voltage.
Dynamic response also matters. A charger that starts up or changes mode produces current steps, and the emulator must hold the voltage without oscillating. And since a charger delivers energy, the source has to absorb it: suitable emulators are bidirectional or have a sink that returns the energy to the grid or dissipates it.
What can be tested
- Charger charging profile with different initial states of charge.
- Response to battery limit voltages and to the sudden opening of contactors.
- Behavior under overvoltage or sudden load disconnection.
- Efficiency at different operating points.
What the engineer sees
If the model is too simple, the equipment under test works well on the bench and fails with the real battery, because real internal resistance depends on temperature and current. For this reason it is advisable to validate the model against measured data from the battery to be represented.
Although the emulator has no chemical thermal risk, the voltage and current levels are still hazardous and require qualified personnel.