The basic function
The battery delivers direct current, but the most common traction motors run on three-phase alternating current. The inverter sits between them: using electronic power switches, it generates three alternating voltages from the DC bus. Varying the frequency controls the speed; varying the amplitude and the angle of the current relative to the motor field controls the torque.
How it does this
- Switch bridge: power semiconductors, such as IGBTs or MOSFETs, switch at high frequency.
- Pulse-width modulation: the effective voltage is built by varying the on-time of each switch. The motor inductance smooths the current.
- Motor control: a controller measures currents and rotor position and calculates the switching signals in real time. Field-oriented control is common.
- DC bus capacitor: dampens ripple and supplies the switching current peaks.
- Cooling: switching and conduction losses are removed by liquid or air.
Regenerative braking
The same bridge can work in reverse. During deceleration, the motor acts as a generator and the inverter rectifies its output to return energy to the battery. This capability depends on the state of charge and temperature of the battery.
What a technician observes
- Fault codes for overcurrent, overtemperature or bus undervoltage.
- Power loss from thermal limiting, which activates before the semiconductors are damaged.
- Electromagnetic noise from fast switching, which affects sensors and communications if shielding or grounding is poor.
- Insulation degradation between the high-voltage circuit and the chassis, monitored by a vehicle insulation monitor.
Interpretation errors
- Thinking that the inverter “makes power grow”: it only transforms the battery’s energy, with losses.
- Confusing it with the onboard charger, which converts from AC to DC.
- Attributing every traction fault to the motor without checking the inverter, the wiring and the DC bus.
- Measuring switching voltages with instruments that lack adequate bandwidth or category.
Safety
The high-voltage systems of an electric vehicle can cause lethal shocks, and the bus capacitor retains charge for some time after disconnection. Any work must be carried out by qualified, trained personnel, following the manufacturer’s procedures and the applicable regulations.