How is soiling loss evaluated?

Soiling loss is evaluated by comparing the output of a clean module or cell with that of an identical one exposed without cleaning. The ratio between the two, normally of the short-circuit current, gives the fraction of energy lost to dust.

The basic method

Two identical devices are installed in the same plane and with the same orientation, one kept clean and the other left exposed to the same conditions as the array. Since soiling mainly reduces the irradiance reaching the cell, the short-circuit current is a good indicator, as it is almost proportional to the light received. The quotient of the soiled device’s current and the clean device’s current is the soiling ratio.

Why short-circuit current is used

Voltage depends more on temperature than on light, and power combines both. Short-circuit current isolates the optical effect of soiling. If power is used, it must be corrected for temperature so as not to confuse the effects.

Alternative methods

  • Comparing the performance ratio before and after a cleaning, under the same conditions.
  • Measuring the I-V curve of modules before and after cleaning them.
  • Estimating with models based on rainfall, airborne dust and time since the last cleaning, although these require on-site validation.

What an engineer sees in the field

The loss grows with the days without rain and falls after sufficient rain or a cleaning. Soiling is not usually uniform: the lower edges of the modules and areas with bird droppings or close to roads contribute greater losses in certain strings, and that non-uniformity also causes mismatch.

How to interpret the result

The measured loss is used to estimate the energy that cleaning would recover, which is compared with the cost of cleaning to set its frequency. The cleaning method must protect the glass and frames, avoiding abrasives. Work on roofs requires fall protection measures.