How is battery storage integrated into a solar system?

Storage is integrated into a solar system on the DC side, with a hybrid inverter, or on the AC side, with a separate battery inverter. The choice defines the coupling, the backup during blackouts and the way the system is sized.

Two ways to couple

  • DC coupling: the array and the battery share a hybrid inverter or a DC-DC converter. Solar energy charges the battery without going through conversion twice, which reduces losses.
  • AC coupling: the battery has its own inverter-charger connected on the AC side, alongside a conventional solar inverter. It is simpler to add to an existing system.

What must be defined first

The objective shapes the design: increasing self-consumption, shifting consumption to more expensive hours, backing up critical loads during blackouts or operating off-grid. Each objective changes the power and energy required. The battery’s power defines how much load it can supply at once; its capacity defines for how long.

The role of the battery management system

The battery communicates with the inverter to report state of charge, current and voltage limits, and alarms. The inverter adjusts its charging and discharging according to that information. Misconfigured communication is a common reason why the system does not charge or discharge as expected.

Backup during blackouts

To supply loads during a grid failure, the system must be able to isolate itself from the grid and form its own local grid. This is done with a separate critical loads panel and equipment that performs the transfer safely. Not all battery systems offer this function.

What an engineer sees in practice

During commissioning, the polarities, communication, charging parameters, discharge limits and transfer to island mode are verified. During operation, the daily charge and discharge curves, the battery temperature and the alarms are reviewed.

Notice

Batteries store energy even without sun and present electrical, thermal and chemical hazards. Design and installation must be carried out by qualified persons, in accordance with the applicable regulations and the manufacturer’s instructions.