What is a power optimizer?

A power optimizer is a DC-DC converter fitted to each module so that it works at its maximum power point, while conversion to alternating current is still done by a string inverter.

What exactly it does

The optimizer performs maximum power point tracking for its module and delivers the energy to the string at a suitable voltage and current. A single inverter then converts direct current to alternating current. In other words, optimization is per module and inversion remains centralized per string.

Why it improves behavior under shading

In a series string, the current is common and the shaded module limits the others. When each module is decoupled by its own converter, the current of each one can differ and the string adjusts through voltage. The shaded module loses its own share, but does not drag the rest down to the same extent.

Difference from a microinverter

  • The optimizer delivers DC; the microinverter delivers AC.
  • With optimizers there is still a string inverter and DC wiring running to it.
  • Optimizers usually require a compatible inverter, because they communicate with it and regulate the string voltage.
  • In both cases there are electronics on the roof, exposed to temperature and the weather.

Rapid shutdown

A common function of these devices is to reduce the array voltage when communication with the inverter or its power supply is cut. This helps limit the voltage present on the roof during an emergency, and it is one reason they are chosen for installations where regulations require reducing the risk to firefighters and technicians.

How to interpret the benefit

The gain depends on the degree of mismatch between modules: partial shading, mixed orientations or modules of different ages. In a uniform, clean array, the difference from a conventional string inverter is small, and the optimizer adds points of failure and its own conversion losses. That is why the evaluation must be based on the site and not on a general rule.

Notice

Any work on an energized PV array, with DC voltages that are not interrupted by opening a disconnect on the AC side, must be carried out by qualified personnel, following the applicable electrical safety regulations.