The performance ratio of a solar plant compares the energy actually delivered with what an ideal system would have produced under the same irradiation; it sums up the losses from temperature, soiling, wiring, the inverter and availability.

Definition

The performance ratio, or PR, is the quotient of the energy the plant actually delivers and the theoretical energy it would deliver if all its modules always operated at their rated power under the irradiation received. It is dimensionless and is expressed as a fraction or a percentage.

Why it is normalized to irradiation

Comparing the energy produced by plants of different sizes, or in a sunny month and a cloudy one, says nothing about their performance. The PR solves this by dividing by the plane-of-array irradiation and the installed capacity. What remains is a measure of how well the plant converts the available solar energy, independent of the resource.

What losses it sums up

  • Temperature: hot modules produce less.
  • Soiling and shading.
  • Reflection and angle of incidence effects.
  • Mismatch between modules and wiring losses.
  • Inverter conversion and transformer losses.
  • Unavailability: shutdowns, faults and grid limitations.
  • Degradation of the modules.

What an engineer sees in practice

The PR is calculated by day, month or year and tracked over time. A sudden drop points to a fault or shutdown; a gradual loss, to soiling or degradation. Over an annual cycle, the PR varies with temperature: it is usually lower in the hot season and higher in the cold season, because of the effect of the temperature coefficient.

How to interpret the result

  • It is not the same as module efficiency; it is a system measure.
  • It depends on how irradiation was measured: a poorly calibrated sensor, or one in another plane, alters the value.
  • Comparing plants in different climates without correcting for temperature can be misleading.
  • A plant with prolonged shutdowns will show a low PR even if its modules are in good condition.

It is best interpreted as a trend at a single plant rather than as an isolated number. Electrical work at solar plants must be carried out by qualified personnel in accordance with current regulations.