What is irradiance and how is it expressed?

Irradiance is the power of solar radiation striking a surface per unit area and is expressed in watts per square meter; its integral over time is irradiation, in energy per unit area.

Short answer

Irradiance is power per unit area: how much energy per second reaches each square meter. It is expressed in watts per square meter, W/m². It is the factor that most determines what a module produces, because the photogenerated current is almost proportional to it.

Irradiance and irradiation

These are different quantities that are often confused. Irradiance is instantaneous, a power. Irradiation is the energy accumulated over an interval, the integral of irradiance over time, and is typically expressed in kilowatt-hours per square meter or as equivalent peak sun hours. To estimate daily or annual energy production, use irradiation; to explain how a module is behaving at this instant, use irradiance.

Components of radiation

  • Direct: radiation arriving in a straight line from the solar disk.
  • Diffuse: radiation scattered by the atmosphere and clouds, arriving from the whole sky.
  • Reflected: radiation bouncing off the ground and surroundings, important for bifacial modules.
  • Global: the sum of the above on a given surface.

Why it depends on orientation

Irradiance on a module depends on its tilt and orientation relative to the sun, the angle of incidence and the air mass the radiation passes through. That is why a distinction is made between irradiance on the horizontal plane and plane-of-array irradiance, which is the one relevant to production. Measuring in the wrong plane produces a meaningless comparison.

What an engineer sees in practice

Irradiance is measured with pyranometers or reference cells and logged together with temperature. It changes quickly with clouds, and the performance of a module or plant is normalized to it for comparison. Module power specifications refer to a reference irradiance defined in the standard test conditions, which the manufacturer declares.

How to interpret a reading

An irradiance reading is only useful with its plane, its instrument and its time. Without that information it is of no use for evaluating a system.