What is an authorized entrant?

An authorized entrant is the person designated to enter a permit-required confined space: they know its hazards, use the protective equipment, stay in communication and leave immediately at any sign of alarm.

Definition

The authorized entrant is the person empowered to enter the confined space and do the work inside. Being part of the crew is not enough: they must be identified on the permit or the entry log, have been trained and be known to the attendant and the supervisor.

What they must know

  • The hazards of the space, including atmospheric, mechanical and engulfment hazards, and how they show up: symptoms of exposure, alarms and changes in conditions.
  • The controls in place: ventilation, isolation, protective equipment and the limits of the permit.
  • The correct use of the communication equipment, the harness and any detector they carry.
  • The emergency plan and the exit route.

What they must do

  • Enter only after the supervisor authorizes the permit and the attendant is at the post.
  • Use the specified equipment, such as a harness with an extraction line when applicable.
  • Stay in communication with the attendant and report any problem.
  • Stay within the limits of the permit, with no work other than what was planned.

When they must leave without waiting

On an order from the attendant or the supervisor, on a detector alarm, if a symptom such as dizziness, headache or difficulty breathing appears, or if they perceive a new hazard. The decision to leave needs no prior justification. Being able to stop work without being penalized is an essential part of the safety culture.

What an engineer sees in practice

Workers who carry their personal detector, respect the count of entries and exits and do not go in “just for a moment” without authorization. The usual risk is overconfidence: someone who has entered many times stops respecting the steps.

How to interpret the role

It is a responsibility shared with the other roles in the system. Designation and training must comply with the applicable safety regulations, and the activity belongs to qualified personnel.