How do you inspect a silo or hopper?

Inspecting a silo or hopper involves its own risks: engulfment by material, a deficient or explosive atmosphere, combustible dust, and material that sticks and then falls. That is why it is emptied, isolated and locked out, and entered only with a permit and a harness.

First of all: is entry necessary?

The safest inspection is one that does not require entry. Many visual checks of a silo or hopper can be done from an inspection opening, with a camera, with level measuring equipment or by remote inspection. Entry is reserved for what cannot be assessed any other way.

Why it is so dangerous

Bulk materials behave like a dangerous fluid. Grain or powder can flow toward the outlet and bury a person in seconds; a column of material stuck to the wall, known as a bridge or arch, can collapse without warning when disturbed. A person standing on flowing material cannot get out unaided, because the material compresses the body and restricts movement.

Other hazards

  • Atmosphere: fermentation or oxidation of the material can consume oxygen or generate gases such as carbon dioxide; some products give off toxic gases.
  • Combustible dust: in suspension, an organic or metallic dust can cause an explosion if it finds an ignition source.
  • Heat and self-ignition: material that heats up from within.
  • Equipment: conveyors, valves and screw conveyors that could start up during the work.

How entry is prepared

  1. Empty the silo as far as possible and isolate any sources that could load material.
  2. Lock out and tag out all energized equipment, and close the feed and discharge accesses.
  3. Measure the atmosphere and ventilate; control ignition sources and suspended dust.
  4. Assess the condition of the remaining material and any bridges before approaching.
  5. Enter with a permit, a harness attached to an extraction system from outside, an attendant and communication.

What an engineer sees in practice

Material that looks stable but gives way, crusted walls and poor visibility because of dust. Walking on the material is avoided, cleaning is done from above with tools when possible, and care is taken that nobody works beneath an unsupported buildup.

How to interpret the condition

If there is material suspended above the work point, if equipment isolation has not been verified or if the atmosphere is not reliable, the inspection does not begin. These activities must be carried out by qualified, trained personnel, under the applicable safety regulations.